background image

15

English

How to use

Auto Restart Control

• If power is resumed after a power failure, the 

operation will restart automatically after a period 

of time with previous operation mode and air

fl

 ow 

direction. 

• This control is not applicable when TIMER is set.

POWERFUL/

QUIET

To switch between powerful & 
quiet

QUIET

POWERFUL

NORMAL

POWERFUL: To reach temperature quickly

POWERFUL/QUIET

• This operation stops automatically after 15 minutes.

QUIET: To enjoy quiet operation

POWERFUL/QUIET

• This operation reduces air

fl

 ow noise.

FAN SPEED

To select fan speed

(Remote control display)

AUTO

FAN

• For AUTO, the indoor fan speed is automatically 

adjusted according to the operation mode.

AIR SWING

To adjust vertical airfl ow direction
(CS-RE9SKA, CS-RE12SKA)

(Remote control display)

• Keeps the room ventilated.

• In COOL/DRY mode, if AUTO is set, the 

fl

 ap swings 

up/down automatically.

• In HEAT mode, if AUTO is set, the horizontal 

fl

 ap is 

fi

 xed at the predetermined position.

• Do not adjust the 

fl

 ap by hand.

AIR SWING

To adjust airfl ow direction
(CS-RE18SKA, CS-RE24SKA)

(Remote control display)

• Keeps the room ventilated.

• In COOL/DRY mode, if AUTO is set, the 

fl

 aps swings 

left/right and up/down automatically.

• In HEAT mode, if AUTO is set, the horizontal 

fl

 ap is 

fi

 xed at the predetermined position. The vertical 

fl

 ap 

swings left/right after the temperature rises.

• If manual is set, the horizontal and vertical 

fl

 ap are 

fi

 xed at the predetermined position.

• Do not adjust the 

fl

 ap by hand.

To set the timer

2 sets of ON and OFF timers are available to turn 
ON or OFF the unit at different preset times.

ON

OFF

SET

CANCEL

1

2

3

TIMER

CANCEL

3

TIMER

1

2

3

1

Select ON or OFF timer

Example: 
OFF at 22:00

• Each time pressed:

OFF

Cancel

2

Set the time

2

3

Confi rm

SET

TIMER

• To cancel ON or OFF timer, press 

ON

 or 

OFF

 to 

select respective   or   then press 

CANCEL

.

• If timer is cancelled manually or due to power 

failure, you can restore the timer again by 
pressing 

ON

 or 

OFF

 to select respective   or 

 then press 

SET

.

• The nearest timer setting will be displayed and 

will activate in sequence.

• When ON Timer is set, the unit may start earlier 

(up to 30 minutes) before the actual set time 
in order to achieve the desired temperature on 
time.

• Timer operation is based on the clock set in the 

remote control and repeats daily once set. For 
clock setting, please refer to Quick guide.

Note

POWERFUL/

QUIET

 , 

nanoe-G

 , 

SLEEP

• Can be activated in all modes and can be 

cancelled by pressing the respective button 
again.

POWERFUL/

QUIET

• Cannot be selected at the same time.

Summary of Contents for CS-RE9SKA

Page 1: ...RE24SKA Operating Instructions Air Conditioner ACXF55 00680 2 9 18 Panasonic Operating Instructions Air Conditioner 10 18 Thank you for purchasing Panasonic Air Conditioner Installation instructions a...

Page 2: ...2 4 5 6 7 8 9 18 AAA R03 2 2 DBT WBT C DBT WBT DBT WBT COOL 32 23 43 26 16 11 16 11 HEAT 30 24 18 16 5 6 nanoe G...

Page 3: ...T CANCEL 1 2 3 TIMER CLOCK SET CHECK RESET AC RC MODE POWERFUL QUIET AIR SWING FAN SPEED nanoe G SLEEP CS RE9SKA CS RE12SKA AIR CONDITIONER OFF ON ON OFF SET CANCEL 1 2 3 TIMER nanoe G SLEEP MODE TEMP...

Page 4: ...4...

Page 5: ...5 ELCB RCD ELCB GB ON COOL DRY Ni Cd...

Page 6: ...OFF ON ON OFF SET CANCEL 1 2 3 TIMER nanoe G SLEEP MODE TEMP FAN SPEED CLOCK SET CHECK RESET AC RC MODE AIR SWING POWERFUL QUIET OFF ON ON OFF SET CANCEL 1 2 3 TIMER TEMP CLOCK CHECK AIR CONDITIONER...

Page 7: ...UTO AIR SWING CS RE9SKA CS RE12SKA COOL DRY AUTO HEAT AUTO AIR SWING CS RE18SKA CS RE24SKA COOL DRY AUTO HEAT AUTO ON OFF ON OFF ON OFF SET CANCEL 1 2 3 TIMER CANCEL 3 TIMER 1 2 3 1 ON OFF 22 00 OFF O...

Page 8: ...oe G POWER FUL QU IET nanoe G H99 pH 7 40 C POWER TIMER nanoe G POWERFU L QUIET 1 2 2 3 4 CS RE18SKA CS RE24SKA POWER TIMER nanoe G POWERFU L QUIET 1 nanoe G 2 2 OFF ON COOL HEAT 15 COOL 8 C HEAT 14 C...

Page 9: ...9 30 TIMER POWER ON nanoe G HEAT COOL TIMER ON OFF SET CANCEL 1 2 3 TIMER CLOCK SET CHECK RESET AC RC ON OFF SET CANCEL 1 3 TIMER CLOCK SET RESET AC RC 5 2 1 5 3 4 4...

Page 10: ...ioner under the following temperature range DBT Dry bulb temperature WBT Wet bulb temperature Temperature C Indoor Outdoor DBT WBT DBT WBT COOL Max 32 23 43 26 Min 16 11 16 11 HEAT Max 30 24 18 Min 16...

Page 11: ...CLOCK SET CHECK RESET AC RC MODE AIR SWING POWERFUL QUIET AIR CONDITIONER ON OFF SET CANCEL 1 2 3 TIMER nanoe G SLEEP FAN SPEED CLOCK SET CHECK RESET AC RC MODE AIR SWING POWERFUL QUIET CS RE18SKA CS...

Page 12: ...ric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc...

Page 13: ...ly strong lightning activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for pres...

Page 14: ...tor blinks during this operation COOL mode To enjoy cool air Provides efficient comfort cooling to suit your needs DRY mode To dehumidify the environment Unit operates at low fan speed to give a gentl...

Page 15: ...d up down automatically In HEAT mode if AUTO is set the horizontal flap is fixed at the predetermined position The vertical flap swings left right after the temperature rises If manual is set the hori...

Page 16: ...ER TIMER nanoe G POWERFU L QUIET Insert at both sides 1 nanoe G Generator Once every 2 weeks Clean with dry cotton bud Do not touch during operation Air filters Once every 2 weeks Wash rinse the filte...

Page 17: ...negative ions from nanoe G Remove the dust regularly with a clean dampened cloth Check the following before calling for servicing Symptom Check Operation in HEAT COOL mode is not working efficiently S...

Page 18: ...symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symb...

Page 19: ...19 Memo...

Page 20: ...ACXF55 00680 SS1215 0 Printed in Malaysia Panasonic Corporation Website http www panasonic com Panasonic Corporation 2015...

Reviews: