background image

14

How to use

To adjust horizontal airfl ow 
direction

• Manually adjustable.

(CS-RE9SKA, 

 CS-RE12SKA)

Auto OFF/ON button

Use when remote control is misplaced or a 

malfunction occurs. Raise the front panel:
• To use in AUTO mode, press the button once.  

• To use in COOL mode, press and hold the button 

until 1 beep is heard, then release.

• To use in HEAT mode, press and hold the button 

until 1 beep is heard, then release. And press 

again until 2 beeps, then release.   

• Press the button again to turn off.

Remote control receiver and indicator

POWER

TIMER

nanoe-G

POWERFUL/QUIET

(Green)
(Orange)
(Blue)
(Orange/Green)

nanoe-G

To purify the air

nanoe-G

• nanoe-G starts automatically when the unit is turned 

on with 

OFF/ON

 .

• Can be activated even when the unit is turned off. In 

this condition, the unit will operate as a fan with AUTO 

fan speed and 

fl

 ap swing.

To deactivate viruses/bacteria on the fi lter

nanoe-G

POWER

• After the unit is turned off, the nanoe-G in-

fi

 lter 

deactivation may activate up to 150 minutes. Turning 

on the unit cancels this operation.

MODE

To select operation mode

AUTO mode - For your convenience

• During operation mode selection the POWER 

indicator blinks.

• Unit selects operation mode every 10 minutes 

according to setting temperature and room 

temperature.

HEAT mode - To enjoy warm air

• Unit takes a while to warm up. The POWER indicator 

blinks during this operation.

COOL mode - To enjoy cool air

• Provides ef

fi

 cient comfort cooling to suit your needs.

DRY mode - To dehumidify the environment

• Unit operates at low fan speed to give a gentle cooling 

operation.

SLEEP

To maximise comfort while 
sleeping

(CANCEL)

• This operation provides you with a comfortable 

environment while sleeping. It will automatically adjust 

the sleep pattern temperature during the activation 

period.

• The indoor unit indicator will dim when this operation 

is activated. This is not applicable if the indicator 

brightness has been manually dimmed.

• This operation is incorporated with the activation timer 

(0.5, 1, 2, 3, 4, 5, 6, 7, 8 or 9 hours).

• This operation can be set together with single timer or 

twin timer. Sleep operation has the priority over OFF 

timer.

• This operation can be cancelled by pressing the 

respective button when the sleep timer reaches 0.0h.

AIR CONDITIONER

OFF/ON

ON

OFF

SET

CANCEL

1

2

3

TIMER

nanoe-G

SLEEP

MODE

TEMP

FAN SPEED

CLOCK

SET

CHECK

RESET

AC

RC

MODE

AIR SWING

POWERFUL/

QUIET

OFF/ON

ON

OFF

SET

CANCEL

1

2

3

TIMER

TEMP

CLOCK

CHECK

AIR CONDITIONER

OFF/ON

ON

OFF

SET

CANCEL

1

2

3

TIMER

MODE

TEMP

CLOCK

SET

CHECK

RESET

AC

RC

MODE

POWERFUL/

QUIET

AIR SWING

FAN SPEED

nanoe-G

SLEEP

OFF/ON

ON

OFF

SET

CANCEL

1

2

3

TIMER

TEMP

CLOCK

CHECK

Remote control 

display

CS-RE9SKA,

CS-RE12SKA

CS-RE18SKA,

CS-RE24SKA

Press to restore the remote 

control to default setting.

Press and hold for approximately 10 seconds to 

show temperature setting in °C or °F.

Not used in normal operations.

Summary of Contents for CS-RE9SKA

Page 1: ...RE24SKA Operating Instructions Air Conditioner ACXF55 00680 2 9 18 Panasonic Operating Instructions Air Conditioner 10 18 Thank you for purchasing Panasonic Air Conditioner Installation instructions a...

Page 2: ...2 4 5 6 7 8 9 18 AAA R03 2 2 DBT WBT C DBT WBT DBT WBT COOL 32 23 43 26 16 11 16 11 HEAT 30 24 18 16 5 6 nanoe G...

Page 3: ...T CANCEL 1 2 3 TIMER CLOCK SET CHECK RESET AC RC MODE POWERFUL QUIET AIR SWING FAN SPEED nanoe G SLEEP CS RE9SKA CS RE12SKA AIR CONDITIONER OFF ON ON OFF SET CANCEL 1 2 3 TIMER nanoe G SLEEP MODE TEMP...

Page 4: ...4...

Page 5: ...5 ELCB RCD ELCB GB ON COOL DRY Ni Cd...

Page 6: ...OFF ON ON OFF SET CANCEL 1 2 3 TIMER nanoe G SLEEP MODE TEMP FAN SPEED CLOCK SET CHECK RESET AC RC MODE AIR SWING POWERFUL QUIET OFF ON ON OFF SET CANCEL 1 2 3 TIMER TEMP CLOCK CHECK AIR CONDITIONER...

Page 7: ...UTO AIR SWING CS RE9SKA CS RE12SKA COOL DRY AUTO HEAT AUTO AIR SWING CS RE18SKA CS RE24SKA COOL DRY AUTO HEAT AUTO ON OFF ON OFF ON OFF SET CANCEL 1 2 3 TIMER CANCEL 3 TIMER 1 2 3 1 ON OFF 22 00 OFF O...

Page 8: ...oe G POWER FUL QU IET nanoe G H99 pH 7 40 C POWER TIMER nanoe G POWERFU L QUIET 1 2 2 3 4 CS RE18SKA CS RE24SKA POWER TIMER nanoe G POWERFU L QUIET 1 nanoe G 2 2 OFF ON COOL HEAT 15 COOL 8 C HEAT 14 C...

Page 9: ...9 30 TIMER POWER ON nanoe G HEAT COOL TIMER ON OFF SET CANCEL 1 2 3 TIMER CLOCK SET CHECK RESET AC RC ON OFF SET CANCEL 1 3 TIMER CLOCK SET RESET AC RC 5 2 1 5 3 4 4...

Page 10: ...ioner under the following temperature range DBT Dry bulb temperature WBT Wet bulb temperature Temperature C Indoor Outdoor DBT WBT DBT WBT COOL Max 32 23 43 26 Min 16 11 16 11 HEAT Max 30 24 18 Min 16...

Page 11: ...CLOCK SET CHECK RESET AC RC MODE AIR SWING POWERFUL QUIET AIR CONDITIONER ON OFF SET CANCEL 1 2 3 TIMER nanoe G SLEEP FAN SPEED CLOCK SET CHECK RESET AC RC MODE AIR SWING POWERFUL QUIET CS RE18SKA CS...

Page 12: ...ric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc...

Page 13: ...ly strong lightning activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for pres...

Page 14: ...tor blinks during this operation COOL mode To enjoy cool air Provides efficient comfort cooling to suit your needs DRY mode To dehumidify the environment Unit operates at low fan speed to give a gentl...

Page 15: ...d up down automatically In HEAT mode if AUTO is set the horizontal flap is fixed at the predetermined position The vertical flap swings left right after the temperature rises If manual is set the hori...

Page 16: ...ER TIMER nanoe G POWERFU L QUIET Insert at both sides 1 nanoe G Generator Once every 2 weeks Clean with dry cotton bud Do not touch during operation Air filters Once every 2 weeks Wash rinse the filte...

Page 17: ...negative ions from nanoe G Remove the dust regularly with a clean dampened cloth Check the following before calling for servicing Symptom Check Operation in HEAT COOL mode is not working efficiently S...

Page 18: ...symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symb...

Page 19: ...19 Memo...

Page 20: ...ACXF55 00680 SS1215 0 Printed in Malaysia Panasonic Corporation Website http www panasonic com Panasonic Corporation 2015...

Reviews: