34
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated
above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature. When the air
conditioner is stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control. The angels of the vane are as stated above. When the air
conditioner is stopped using remote control, the vane will shift to close position.
* Above angle data is for reference only.
12.3.2 Horizontal
Airflow
The horizontal airflow direction louvers can be adjusted manually by hand.
12.3.3 Quiet operation
ϥ
To provide quiet operation comparing to normal operation. The Quiet operation can be active or stop by pressing
QUIET/POWERFUL button on remote control.
ϥ
Once Quiet mode is active ,the unit will continuously operate in QUIET Mode until cancel the mode by pressing
QUIET/POWERFUL button on remote control.
12.3.4 Powerful
operation
ϥ
To cooling or heating the room faster comparing to normal operation. The POWERFUL operation can be active or
stop by pressing QUIET/POWERFUL button
RQ
remote control.
ϥ
When powerful operation is active, the unit will continuously operate in POWERFUL mode until cancel the mode
by pressing QUIET/POWERFUL button on remote control. Operation details are as the fig. below.
1. For cooling, soft Dry mode
Power Button pressed
PIPING
TEMP.
(COOLING)
FAN SPEED
( rpm)
ON
OFF
AUTO
45 seconds
20 ‘
Shi
20 ‘
Fast Cooling
Cooling, Soft Dry
Min.5’
Correction
Factor(
)
ć
-0.25
+0.25
-1.67
-1.00
A
B
C
D
20 ‘
20 ‘
1130 (Max)
730 (Min.)
2. For
Heating
mode:
Power Button pressed
ON
OFF
AUTO
45 seconds
20 ‘
Shi
20 ‘
Fast Heating1
Heating
Min.5’
+0.25
+0.25
+2
+1.00
A
B
C
D
20 ‘
20 ‘
1270 (Max)
940 (Min.)
PIPING
TEMP.
(COOLING)
FAN SPEED
( rpm)
Correction
Factor(
)
ć
Note: The value of A, B, C, D will change according to the indoor temperature.
Summary of Contents for CS-RE12JKE
Page 14: ...14 5 2 Outdoor Unit Unit mm ...
Page 15: ...15 6 Refrigeration Cycle Diagram CS CU RE9JKE CS CU RE12JKE CS CU RE15JKE COOLING HEATING ...
Page 16: ...16 7 Block Diagram CS CU RE15JKE CS CU RE9 12JKE ...
Page 17: ...17 8 Wiring Diagram 6 8 5 6 8 5 ...
Page 18: ...18 6 8 5 ...
Page 19: ...19 9 Printed Circuit Board 9 1 Indoor Unit 9 1 1 Main Printed Circuit Board TOP VIEW ...
Page 20: ...20 BOTTOM VIEW ...
Page 21: ...21 9 1 2 Indicator receiver TOP VIEW BOTTOM VIEW ...
Page 22: ...22 9 2 Outdoor Unit 9 2 1 CU RE9JKE CU RE12JKE TOP VIEW BOTTOM VIEW ...
Page 25: ...25 10 2 3 Indoor Unit Installation ...
Page 42: ...42 14 2 3 Error Codes Table ...
Page 48: ...48 16 2 Outdoor Unit CU RE9JKE CU RE12JKE ...
Page 50: ...50 CU RE15JKE ...