36
12.7. Outdoor Fan Speed Control
• There is only one speed for outdoor fan motor.
• When the air conditioner is turned on, the compressor and the outdoor fan will operate simultaneously.
• Likewise, both compressor and outdoor fan will stop at the same time if the unit is turned off.
12.8. Vertical Airflow Direction Control
12.8.1.
Auto Control
(Cooling and Soft Dry Operation condition)
• When the vertical airflow direction is set to Auto using the
remote control, the louver swings up and down as shown in
the diagram.
• When stop operation using the remote control, the discharge
vent is reset, and stop at the closing position.
• During Cooling operation or Soft Dry operation, indoor fan
motor may stop to rotate at certain periods. At that condition,
the louver will stop swinging and rest at the upper limit.
• During dew prevention control, Airflow Direction Auto-control
angle change from 10
°
-38
°
to 10
°
-27
°
under Cooling and
Soft Dry operation mode.
(Heating Operation condition)
• When the piping air temperature reaches 38°C, the louver is
changed from upper to lower limit. When the piping air
temperature falls to 35°C, the louver is changed from lower
to upper limit.
Cooling and Soft Dry Operation
Heating Operation
12.8.2.
Manual Control
• When the vertical airflow direction is set to Manual using the remote control, the automatic airflow is released and the airflow
direction louver move up and down in the range shown in the diagram.
• The louver can be adjusted by pressing the button to the desired louver position.
• When stop operation using the remote control, the discharge vent is reset, and stop at the closing position.
• During dew prevention control, Airflow Direction Manual control angle change from 10
°
, 14
°
, 18
°
, 22
°
, 27
°
to 10
°
, 13
°
, 16
°
, 19
°
,
22
°
under Cooling and Soft Dry operation mode.
Cooling and Soft Dry Operation
Heating Operation
Summary of Contents for CS-PW18GKE
Page 8: ...8 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control ...
Page 10: ...10 5 2 Outdoor Unit ...
Page 11: ...11 6 Refrigeration Cycle Diagram ...
Page 12: ...12 7 Block Diagram ...
Page 13: ...13 8 Wiring Connection Diagram ...
Page 14: ...14 9 Electronic Circuit Diagram 9 1 Indoor Unit 9 2 Outdoor Unit ...
Page 15: ...15 10 Printed Circuit Board 10 1 Indoor Unit ...
Page 16: ...16 ...
Page 17: ...17 10 2 Outdoor Unit ...
Page 18: ...18 10 3 Indicator Receiver ...
Page 21: ...21 3 For the embedded piping This can be used for left rear piping left bottom piping also ...
Page 33: ...33 a Normal Deicing Time Diagram b Overload Deicing Time Diagram ...
Page 44: ...44 16 Technical Data 16 1 Thermostat Characteristics 16 1 1 CS PW18GKE ...
Page 46: ...46 16 3 Operation Characteristics 16 3 1 CS PW18GKE CU PW18GKE ...
Page 47: ...47 ...
Page 48: ...48 ...
Page 49: ...49 ...