background image

13

English

Quick guide

1

2

3

Inserting the batteries

1

   Pull out the back cover of 

remote control

2

   Insert AAA or R03 batteries 

(can be used ~ 1 year)

3

   Close the cover

TIMER

SET

CANCEL

ON

OFF

1

2

3

SET CHECK CLOCK

RESET

AC

RC

TIMER

CANCEL

ON

OFF

1

3

SET CHECK

RESET

AC

RC

2

3

1

Clock setting

1

   Press CLOCK

2

   Set the time

3

   Confi rm

AUTO

COMFORT

MODE

POWERFUL/

QUIET

TEMP

OFF/ON

TIMER

SET

CANCEL

ON

OFF

1

2

3

FAN SPEED

MILD DRY

COOLING

SET CHECK CLOCK

RESET

AC

RC

ECONAVI

AIR SWING

MILD

DRY

FAN
SPEED
AIR
SWING

AUTO

COOL

DRY

AUTO

COMFORT

POWERFUL/

QUIET

TIMER

SET

CANCEL

ON

OFF

1

2

3

FAN SPEED

MILD DRY

COOLING

SET CHECK CLOCK

RESET

AC

RC

ECONAVI

AIR SWING

MILD

DRY

FAN
SPEED
AIR
SWING

AUTO

COOL

DRY

1

2

3

8m

Basic operation

1

  Select the desired mode

DRY

AUTO

COOL

2

   Start/stop the operation

POWER

• Please note that the OFF 

indication 

 is on to start. 

3

   Select the desired 

temperature

• Selection range: 

16 °C ~ 30 °C.

• Operating the unit within the 

recommended temperature 
may save energy.
COOL: 26 °C ~ 28 °C. 
DRY :  1 °C ~ 2 °C lower than 

room temperature.

• To dim or restore the unit’s 

indicator brightness, press 

 

and hold for 5 seconds.

• Use remote control within 8 m 

from the remote control receiver 
of the indoor unit.

The illustrations in this manual are for explanation purposes 
only and may differ from the actual unit. They are subject to 
change without notice for future improvement.

Table of contents

Safety precautions ...............

14-15

How to use...........................

16-17

To learn more... ........................

18

Cleaning instructions ................

19

Troubleshooting  .......................

20

Information................................

21

Accessories

• Remote control
• AAA or R03 batteries × 2
• Remote control holder
• Screws for remote control 

holder × 2

Summary of Contents for CS-PS9QKA

Page 1: ...S PS24QKA CU PS9QKA CU PS12QKA CU PS18QKA CU PS24QKA MILD DRY COOLING 2 11 Panasonic Operating Instructions Air Conditioner 12 21 Thank you for purchasing Panasonic Air Conditioner Installation instru...

Page 2: ...2 ECONAVI AUTO COMFORT...

Page 3: ...OFF 1 2 3 FAN SPEED MILD DRY COOLING SET CHECK CLOCK RESET AC RC ECONAVI AIR SWING MILD DRY FAN SPEED AIR SWING AUTO COOL DRY AUTO COMFORT POWERFUL QUIET TIMER SET CANCEL ON OFF 1 2 3 FAN SPEED MILD D...

Page 4: ...4...

Page 5: ...5 ELCB RCD ELCB ON COOL DRY Ni Cd...

Page 6: ...PEED AIR SWING AUTO COOL DRY AIR SWING MILD DRY FAN SPEED AIR SWING AUTO COOL DRY TEMP OFF ON TIMER SET CANCEL ON OFF 1 2 3 CHECK CLOCK ECONAVI MODE AUTO COOL DRY MILD DRY COOLING COOL AUTO POWERFUL Q...

Page 7: ...AIR SWING COOL DRY AUTO ON OFF ON OFF TIMER SET CANCEL ON OFF 1 2 3 AC C CANCEL 3 AC C 2 1 3 1 ON OFF 22 00 OFF OFF Cancel 2 2 3 SET TIMER ON OFF CANCEL ON OFF ON OFF SET ON 15 ECONAVI POWERFUL QUIET...

Page 8: ...ER 10 COOL COOL DRY ECONAVI COOL DRY 1 C ECONAVI ECONAVI AUTO COMFORT AUTO COMFORT COOL 1 C 2 C 3 5 AUTO COMFORT 2 C 1 C 3 AUTO COMFORT 8 AUTO COMFORT LED DBT WBT C DBT WBT DBT WBT COOL 32 23 43 26 16...

Page 9: ...MILD DRY COOLING 1 2 MILD DRY COOLING MILD DRY COOLING 1 2 3 4 CS PS18QKA CS PS24QKA 2 MILD DRY COOLING MILD D COOLI MILD DRY COOLING MILD D COOLI 10 CZ SA22P OFF ON COOL 15 COOL 8 C MILD DRY COOLING...

Page 10: ...10 TIMER POWER ON COOL TIMER TIMER SET CANCEL ON OFF 1 2 3 SET CHECK CLOCK RESET AC RC TIMER SET CANCEL ON OFF 1 3 SET CLOCK RESET AC RC 5 5 2 1 3 4 4...

Page 11: ...11 Pb...

Page 12: ...comfort clean air and optimise energy saving ECONAVI and AUTO COMFORT The sunlight sensor detects the sunlight intensity and helps control cooling temperatures to provide optimum comfort See To learn...

Page 13: ...8m Basic operation 1 Select the desired mode DRY AUTO COOL 2 Start stop the operation POWER Please note that the OFF indication is on to start 3 Select the desired temperature Selection range 16 C 30...

Page 14: ...ce Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire...

Page 15: ...normally strong lightning activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use fo...

Page 16: ...manually POWERFUL QUIET To switch between powerful quiet QUIET POWERFUL NORMAL POWERFUL To reach temperature quickly POWERFUL This operation stops automatically after 15 minutes QUIET To enjoy quiet...

Page 17: ...time in order to achieve the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Quick guide See T...

Page 18: ...ted The sunlight sensor detects sunlight intensity during weather or day night changes and the unit adjusts temperature In a room without window or with thick curtain the sunlight sensor will judge as...

Page 19: ...with water to avoid damage to the filter surface Dry the filters thoroughly under shade away from fire or direct sunlight Replace any damaged filters Remove air filter Attach air filter MILD DRY COOLI...

Page 20: ...g operation Check if the unit has been installed at an incline Close the front panel properly Remote control does not work Display is dim or transmission signal is weak Insert the batteries correctly...

Page 21: ...Union These symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the...

Page 22: ...Memo...

Page 23: ...Memo...

Page 24: ...F569507 SA0214 0 Printed in Malaysia Panasonic Corporation Website http panasonic net Panasonic Corporation 2014...

Reviews: