15.5. Test Run (Forced Cooling Control)
• Test Run can be enable using the switch at the outdoor unit's PCB according to procedure below:
- Set the DS1 to (Cooling Test Run) mode
- Press SW1 for 1 second to test run.
- Be sure to select cooling mode first, and run the unit in this mode for 5 minutes or more.
- Test Run can be cancelled by pressing the SW1 at outdoor unit's PCB.
15.6. Pump down
• Pump down can be enable using the switch at the outdoor unit's PCB according to procedure below:
- To enable pump down operation, at outdoor unit's PCB, set the DS1 to OFF position.
- Press Test Run button for 1 second. Pump down performs for 10 minutes.
- Set the liquid side 3-way valve to close position until when the gauge indicates at 0.01a (0.1kg/cm
2
).
- Immediately set the gas side valve to close position and press SW1 to stop the operation.
Summary of Contents for CS-PC36JKV
Page 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control ...
Page 10: ...10 5 2 Outdoor Unit ...
Page 11: ...11 6 Refrigeration Cycle Diagram ...
Page 12: ...12 7 Block Diagram ...
Page 13: ...13 8 Wiring Connection Diagram 8 1 Indoor Unit 8 2 Outdoor Unit ...
Page 14: ...14 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 15: ...15 9 2 Outdoor Unit ...
Page 16: ...16 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 17: ...17 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board ...
Page 18: ...18 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Page 41: ...41 16 1 3 To remove discharge grille ...
Page 42: ...42 16 1 4 To remove control board 16 1 5 To remove cross flow fan and indoor fan motor ...
Page 43: ...43 ...
Page 44: ...44 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...
Page 45: ...45 17 2 Operation Characteristics ...
Page 46: ...46 ...
Page 49: ...49 18 2 Outdoor Unit ...
Page 50: ...50 ...