10.3 Airflow Direction
There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by
vertical vanes).
Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat
exchanger temperature and intake air temperature) and manual (angles of direction can be adjusted using
remote control).
10.3.1 Vertical Airflow
Operation
Up-and-down inner vane
Step 1
Step 2
Step 3
Step 4
Step 5
Cooling
Auto
Usual (Ventilation)
[110] degrees – [65] degrees
Control with dew
[110] degrees – [65] degrees
Manual
Usual (Ventilation)
[110°]
110°
90°
70°
[65°]
Control with dew
[110°]
110°
90°
70°
[65°]
Dry
Auto
Usual
[110] degrees – [65] degrees
Control with dew
[110] degrees – [65] degrees
Manual
Usual
[110°]
110°
90°
70°
[65°]
Control with dew
[110°]
110°
90°
70°
[65°]
Heating
Manual
[110°]
110°
100°
90°
[80°]
Auto
A zone
[110°]
B zone
[90°]
C zone
[110°]
Operation
Up-and-down outer vane
Step 1
Step 2
Step 3
Step 4
Step 5
Cooling
Auto
Usual (Ventilation)
[55] degrees – [85] degrees
Control with dew
[55] degrees – [85] degrees
Manual
Usual (Ventilation)
[55°]
62°
72°
83°
[85°]
Control with dew
[55°]
62°
72°
83°
[85°]
Dry
Auto
Usual
[55] degrees – [85] degrees
Control with dew
[55] degrees – [85] degrees
Manual
Usual
[55°]
[55°]
[55°]
[55°]
[55°]
Control with dew
[55°]
[55°]
[55°]
[55°]
[55°]
Heating
Manual
[55°]
62°
72°
83°
[90°]
Auto
A zone
[55°]
B zone
[83°]
C zone
[62°]
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the
angles as stated above. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop. When the air conditioner is
stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and
the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the
vane will shift to close position.
58°C
50°C
Indoor Heat
Exchanger Temperature
37°C
30°C
C
A
Figure 1
B