background image

14

How to Use

nanoeX

To adjust air

fl

 ow direction 

To adjust air

fl

 ow direction

Upper direction

• Do not adjust the 

fl

 ap by hand.

*  For details operation, refer “To 

Learn More....”

Lateral direction:

• For lateral direction, it is 

manually adjustable as shown.

FAN SPEED:

• When FAN AUTO is selected, the fan speed is adjusted 

automatically according to the operation mode.

• Select the lowest fan speed   to have a low noise operation.

QUIET:

• This operation reduces air

fl

 ow noise.

To adjust FAN SPEED and QUIET condition

• This operation provides cleaner air, moisturises your skin 

and hair, and deodorises odours in the room.

• Press nanoe™X to activate this operation, either when the 

unit is ON or OFF. During nanoe™X individual operation, 

the fan speed will follow the remote control setting.

• If nanoe™X is activated before the unit is turned off, the 

nanoe™X operation will resume when the unit is turned 

on. This includes when TIMER ON is set.

• Press the button again to cancel.

Multi • When the unit is turn off, nanoe™X individual 

operation cannot be performed or will be stopped 

if other indoor unit is activating HEAT mode.

• This operation is automatically stop after 20 minutes.
• Press the button again to cancel.

To reach the desired temperature quickly

POWERFUL

(exit setting)

To enjoy fresher and cleaner environment

• This operation reduces air dryness during COOL mode only.
• Press the button again to cancel.

To improve humidity and moisture level 
(Not applicable for Multi split system)

Indicators

POWER

TIMER

nanoeX

Lateral 
direction

(swing)

(swing)

(exit setting)

Not used 

in normal 

operation.

Press to restore the 

remote control to 

default setting.

Press to turn 

the Wireless 

LAN feature 

ON or OFF.

Summary of Contents for CS-MTZ16ZKE

Page 1: ...ZKE CU RZ35ZKE CU RZ50ZKE Multi Split CU 2Z35TBE CU 2Z41TBE CU 2Z50TBE CU 3Z52TBE CU 3Z68TBE CU 4Z68TBE CU 4Z80TBE CU 5Z90TBE CU 2TZ41TBE CU 2TZ50TBE CU 3TZ52TBE nanoeX ENGLISH Before operating the un...

Page 2: ...3 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries 3 Close the cover A Clock setting 1 Press CLOCK then press to set the time Press CLOCK for approximately 5 seconds to show t...

Page 3: ...nation purposes only and may differ from the actual unit They are subject to change without notice B Basic operation Thank you for purchasing Panasonic Air Conditioner 1 Press to start stop the operat...

Page 4: ...st to clean the internal parts repair install remove disassemble and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm with authorised dealer or s...

Page 5: ...ical shock or fire Prevent electric shock by switching off the power supply and unplug Before cleaning or servicing When extended non use or During abnormally strong lightning activity CAUTION Indoor...

Page 6: ...working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigera...

Page 7: ...onmental effects such as the danger of water collecting and freezing in relief pipes or the accumulation of dirt and debris h Expansion and contraction of long runs piping in refrigerating systems sha...

Page 8: ...nition and hot metal surfaces away 2 3 Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is awar...

Page 9: ...ode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks...

Page 10: ...in the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall al...

Page 11: ...e pipe work are to take place Ensure that the outlet for the vacuum pump is not close to any potential ignition sources and there is ventilation available OFN oxygen free nitrogen type of inert gas 9...

Page 12: ...rdous condition when charging or discharging the refrigerant To avoid fire or explosion dissipate static electricity during transfer by grounding and bonding containers and equipment before charging d...

Page 13: ...cuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant The evacuation process shall be carried out prior to returning the compressor to the suppl...

Page 14: ...llow the remote control setting If nanoe X is activated before the unit is turned off the nanoe X operation will resume when the unit is turned on This includes when TIMER ON is set Press the button a...

Page 15: ...ll modes Cannot be selected at the same time This operation provides you with a comfortable environment while sleeping It will automatically adjust the sleep pattern temperature during the activation...

Page 16: ...art automatically with the last operation mode and airflow direction This control is not applicable when TIMER is set To Learn More Single Single split system Multi Multi split system Operation mode I...

Page 17: ...43 109 4 26 78 8 46 114 8 26 78 8 Min 16 60 8 11 51 8 10 14 0 10 14 0 HEAT Max 30 86 0 24 75 2 18 64 4 24 75 2 18 64 4 Min 16 60 8 15 5 0 16 3 2 15 5 0 16 3 2 DBT Dry bulb temperature WBT Wet bulb tem...

Page 18: ...rings etc Wipe the unit gently with a soft damp cloth The coils and fans should be cleaned periodically by an authorised dealer Outdoor unit Clean the debris that surround the unit Clear any blockage...

Page 19: ...n room temperature increase Indoor fan stops occasionally during heating operation To avoid unintended cooling effect Indoor fan stops occasionally during automatic fan speed setting This is to help r...

Page 20: ...rly Remote control does not work Display is dim or transmission signal is weak Insert the batteries correctly Replace weak batteries The unit does not work Check if the circuit breaker is tripped Chec...

Page 21: ...nts Use AUTO OFF ON on the unit to select COOL or HEAT mode For details refer The remote control is missing or a malfunction has occurred above After 15 minutes of operation it is normal to have the f...

Page 22: ...35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnormality H 38 Indoor outdoor mismatch brand cod...

Page 23: ...ly valid in the European Union If you wish to discard these items please contact your local authority or dealer and ask for the correct method of disposal Note for the battery symbol bottom two symbol...

Page 24: ...a branch of Panasonic Marketing Europe GmbH Maxis 2 Western Road Bracknell Berkshire RG12 1RT Manufactured by Panasonic Corporation 1006 Oaza Kadoma Kadoma City Osaka 571 8501 Japan Importer Panasonic...

Reviews: