52
17.2 Breakdown Self Diagnosis Function
17.2.1 Self Diagnosis Function (Three Digits Alphanumeric Code)
Once abnormality has occurred during operation,
the unit will stop its operation, and Timer LED
blinks.
Although Timer LED goes off when power supply
is turned off, if the unit is operated under a
breakdown condition, the LED will light up again.
In operation after breakdown repair, the Timer
LED will no more blink. The last error code
(abnormality) will be stored in IC memory.
17.2.2 To Make a Diagnosis
1 Timer LED start to blink and the unit
automatically stops the operation.
2 Press the CHECK button on the remote
controller continuously for 5 seconds.
3 “- -” will be displayed on the remote controller
display.
Note: Display only for “- -”. (No transmitting
signal, no receiving sound and no Power LED
blinking.)
4 Press the “TIMER”
▲
or
▼
button on the
remote controller. The code “H00” (no
abnormality) will be displayed and signal will
be transmitted to the main unit.
5 Every press of the button (up or down) will
increase abnormality numbers and transmit
abnormality code signal to the main unit.
6 When the latest abnormality code on the main
unit and code transmitted from the remote
controller are matched, power LED will light
up for 30 seconds and a beep sound
(continuously for 4 seconds) will be heard. If
no codes are matched, power LED will light up
for 0.5 seconds and no sound will be heard.
7 The breakdown diagnosis mode will be
canceled unless pressing the CHECK button
continuously for 5 seconds or operating the
unit for 30 seconds.
8 The LED will be off if the unit is turned off or
the RESET button on the main unit is pressed.
17.2.3 To Display Memorized Error
(Protective Operation) Status
1 Turn power on.
2 Press the CHECK button on the remote
controller continuously for 5 seconds.
3 “- -” will be displayed on the remote controller
display.
Note: Display only for “- -”. (No transmitting
signal, no receiving sound and no Power LED
blinking.)
4 Press the “TIMER”
▲
or
▼
button on the
remote controller. The code “H00” (no
abnormality) will be displayed and signal will
be transmitted to the main unit.
The power LED lights up. If no abnormality is
stored in the memory, three beeps sound will
be heard.
5 Every press of the button (up or down) will
increase abnormality numbers and transmit
abnormality code signal to the main unit.
6 When the latest abnormality code on the main
unit and code transmitted from the remote
controller are matched, power LED will light
up for 30 seconds and a beep sound
(continuously for 4 seconds) will be heard. If
no codes are matched, power LED will light up
for 0.5 seconds and no sound will be heard.
7 The breakdown diagnosis mode will be
canceled unless pressing the CHECK button
continuously for 5 seconds or operating the
unit for 30 seconds.
8 The same diagnosis can be repeated by
turning power on again.
17.2.4 To Clear Memorized Error
(Protective Operation) Status
after Repair
1 Turn power on (in standby condition).
2 Press the AUTO button for 5 seconds (A beep
receiving sound) on the main unit to operate
the unit at Forced Cooling Operation modes.
3 Press the CHECK button on the remote
controller for about 1 second with a pointed
object to transmit signal to main unit. A beep
sound is heard from main unit and the data is
cleared.
17.2.5 Temporary Operation (Depending
On Breakdown Status)
1 Press the AUTO button (A beep receiving
sound) on the main unit to operate the unit.
(Remote control will become possible.)
2 The unit can temporarily be used until
repaired.
Summary of Contents for CS-MRE7PKE
Page 15: ...15 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control...
Page 16: ...16 5 Dimensions 5 1 Indoor Unit...
Page 17: ...17 5 2 Outdoor Unit...
Page 18: ...18 6 Refrigeration Cycle Diagram...
Page 19: ...19 7 Block Diagram 7 1 Indoor Unit...
Page 20: ...20 7 2 Outdoor Unit...
Page 21: ...21 8 Wiring Connection Diagram 8 1 Indoor Unit...
Page 22: ...22 8 2 Outdoor Unit...
Page 23: ...23 9 Electronic Circuit Diagram 9 1 Indoor Unit...
Page 24: ...24 9 2 Outdoor Unit...
Page 26: ...26 10 2 Outdoor Unit...
Page 53: ...53 17 3 Self Diagnosis Function...
Page 54: ...54...
Page 87: ...87...
Page 88: ...88 19 1 1 2 CS MRE9PKE...
Page 89: ...89...
Page 90: ...90 19 1 2 Two Indoor Unit Operation 19 1 2 1 CS MRE7PKE x2...
Page 91: ...91...
Page 92: ...92 19 1 2 2 CS MRE9PKE CS MRE7PKE...
Page 93: ...93...
Page 95: ...95...
Page 96: ...96 19 2 1 2 CS MRE9PKE...
Page 97: ...97...
Page 98: ...98 19 2 1 3 CS MRE12PKE...
Page 99: ...99...
Page 100: ...100 19 2 2 Two Indoor Unit Operation 19 2 2 1 CS MRE7PKE x2...
Page 101: ...101...
Page 102: ...102 19 2 2 2 CS MRE9PKE x2...
Page 103: ...103...
Page 104: ...104 19 2 2 3 CS MRE12PKE x2...
Page 105: ...105...