Panasonic CS-ME10EB1E Operating Instructions Manual Download Page 2

2

This sign warns of death 

or serious injury.

The appliance is not intended for use by young children or 
infirm person without supervision. Young children should 
be supervised to ensure that they do not play with the 
appliance.

To prevent personal injury, 
injury to others and property 
damage, the following 
instructions must be 
followed.

Incorrect operation due to 
failure to follow instructions 
will cause harm or damage, 
the seriousness of which is 
classified as below:

Thank you for purchasing Panasonic Air Conditioner

SAFETY PRECAUTIONS

This symbol denotes 

an action that is 

PROHIBITED.

These symbols denote 

actions that are 

COMPULSORY.

Warning

N

Definition

This sign warns of injury 

or damage to property.

Caution

The instructions to be 
followed are classified by 
the following symbols:

Safety Regulation

Operation Condition (°C)

Use this air conditioner under the following temperature range.

DBT: Dry Bulb Temperature
WBT: Wet Bulb Temperature

Indoor

Outdoor

DBT

WBT

DBT

WBT

Maximum Temperature (COOL)

32

23

43

26

Maximum Temperature (HEAT)

30

24

18

Minimum Temperature (COOL)

16

11

16

11

Minimum Temperature (HEAT)

16

-10

-11

Caution

•  Use specified supply cord.
•  If the supply cord is damaged or 

needed to be replaced, it must be 
replaced by the manufacturer or its 
service agent or a similarly qualified 
person in order to avoid a hazard.

•  Remove the batteries if the unit is not 

going to be use for a long period of time.

•  New batteries of the same type must 

be inserted following the polarity stated 
to prevent malfunction of the remote 
control.

•  In case of emergency or abnormal 

condition (burnt smell, etc) occurs, turn 
off the power supply.

•  Do not share power outlet.
•  Do not modify power cord.
•  Do not use an extension cord.
•  Do not operate with wet hands.
•   Do not insert finger or other objects into 

the indoor or outdoor unit.

•  Do not attempt to repair the unit by 

yourself.

•  Do not use rechargeable (Ni-Cd) 

batteries.

•  Do not allow infants and small children 

to play with the remote control to 
prevent them from accidentally 
swallowing the batteries. 

•  Do not wash the unit with water, 

benzene, thinner or scouring powder.

•   Do not use for other purposes such as 

preservation of food.

•  Do not use any combustible equipment 

at airflow direction.

•  Do not sit or place anything on the 

indoor or outdoor unit.

•  Do not expose directly to cold air for a 

long period.

•  Ventilate the room regularly.
•  Pay attention as to whether the 

installation rack is damaged after long 
period of usage.

•  Switch off the power supply before 

cleaning or servicing.

•  Turn off the power supply if the unit is 

not used for a long period of time.

Operation Precautions

Warning

Installation Precautions

Do not install, remove and reinstall the unit by yourself.
•  Improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer 

or specialist for the installation work.

•  This equipment must be earthed and installed with ELCB. It may cause electrical shock or fire in 

case of malfunction.

•  Ensure that the drainage piping is connected properly. Otherwise, water will leak.

•  Do not install the unit in a potentially explosive atmosphere.

Caution

Warning

Summary of Contents for CS-ME10EB1E

Page 1: ...eggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento in futuro 18 25 NEDERLANDS Lees voor u het apparaat gebruikt deze gebruiksinstructies grondig na en bewaar ze voor toekomstig gebruik 26 33 PORTUGUÊS Antes de ligar a unidade leia cuidadosamente este manual de utilização e guarde o para futura referência 34 41 ΕΛΛΗΝΙΚΆ Προτού θέσετε τη μονάδα σε λειτουργ...

Page 2: ...erted following the polarity stated to prevent malfunction of the remote control In case of emergency or abnormal condition burnt smell etc occurs turn off the power supply Do not share power outlet Do not modify power cord Do not use an extension cord Do not operate with wet hands Do not insert finger or other objects into the indoor or outdoor unit Do not attempt to repair the unit by yourself Do...

Page 3: ...g operation heating and cooling modes could not be activated at the same time for different indoor unit L The power indicator blinks to indicate the indoor unit is standing by for different operating mode To operate the unit if the remote control is misplaced or malfunctioning Action Operation mode Press once Automatic Operation Press until beep sound and release Cooling Operation Press until beep...

Page 4: ... recycled or disposed of properly 1 Pull out 2 Insert batteries AAA or R03 3 Press CLOCK button 4 Set current time 5 Press again to confirm Check Remote Control Troubleshooting L Remote control display does not work Check whether batteries are correctly inserted or need replacement L The unit cannot operate Check either circuit breaker is tripped or timer is used correctly Ensure OFF indicator does...

Page 5: ...er indicator blinks The operating mode is different from other indoor unit L Operation delayed for a few minutes after restart This is a normal self protection control L Sounds like water flowing during operation Caused by refrigerant flow inside L Cracking sound can be heard during operations Panel expanding contracting due to change in temperature L Occasionally knocking sound is heard Switching o...

Page 6: ...ccasionally during heating operation To avoid unintended cooling effect and prevent continuous increase of room temperature L Air flow continues even after operation has stopped Extraction of remaining heat from the indoor unit maximum 30 seconds L To reduce power consumption during cooling operation close the curtains to prevent the sunlight and heat from coming in L Approximately 10 of electricit...

Page 7: ...ve button again Hint Troubleshooting L Air conditioner does not cool or heat efficiently Ensure the temperature has been set correctly Ensure windows and doors have been closed properly Ensure filters are cleaned or replaced when necessary Ensure inlet and outlet vents of the units have not been obstructed L The unit cannot operate Check either circuit breaker is tripped or timer is used correctly E...

Page 8: ...K button more than 10 seconds to change the time format from 24 hours to AM PM format L For your convenience you could set the air conditioner to operate automatically by using both ON and OFF timer Hints Troubleshooting L TIMER indicator always on Timer is activated and the setting will repeat itself daily L POWER indicator is blinking 60 minutes before ON timer is activated The unit is determini...

Page 9: ...t indoor unit is Operation Temperature Cooling 8 C Heating 14 C 1 Press at 3 places to open 2 Release lever and string to remove Wash and dry INTAKE GRILLE Switch off the power supply before cleaning L Clean the filter regularly as dirty filters will cause unpurified air low cooling or heating capacity unpleasant smells and higher energy consumption L The unit will become dirty and the performance of...

Page 10: ...MEMO ...

Page 11: ...MEMO ...

Page 12: ... gezondheid en voor het milieu omwille van het niet correct hanteren van afval Het ontmantelen en de afvoer van koelmiddel olie en andere delen moet gebeuren door een gekwalificeerd installateur in overeenstemming met de betrokken plaatselijke en nationale bepalingen Airconditioners moeten in een gespecialiseerd bedrijf worden behandeld voor herbruik recycling en recuperatie en mogen niet in de gem...

Reviews: