Panasonic CS-KU18WKYF1 Series Operating Instructions Manual Download Page 6

6

Prevent water leakage by ensuring drainage 
pipe is:
- Connected properly,
- Kept clear of gutters and containers, or
- Not immersed in water
After a long period of use or use with any 
combustible equipment, aerate the room 
regularly.
After a long period of use, make sure the 
installation rack does not deteriorate to 
prevent the unit from falling down.

Remote control

Do not use rechargeable (Ni-Cd) batteries. It 
may damage the remote control.

To prevent malfunction or damage of the 
remote control:
• Remove the batteries if the unit is not going 

to be used for a long period of time.

• New batteries of the same type must be 

inserted following the polarity stated.

Power supply

Do not disconnect the plug by pulling the cord 
to prevent electric shock.

Precaution for using R32 refrigerant

The basic installation work procedures are the same as 
conventional refrigerant (R410A, R22) models.

1. Installation (Space)

• Must ensure the installation of pipe-work 

shall be kept to a minimum. Avoid use 
dented pipe and do not allow acute bending.

• Must ensure that pipe-work shall be 

protected from physical damage.

• Must comply with national gas regulations, 

state municipal rules and legislation. Notify 
relevant authorities in accordance with all 
applicable regulations.

• Must ensure mechanical connections be 

accessible for maintenance purposes.

• In cases that require mechanical ventilation, 

ventilation openings shall be kept clear of 
obstruction.

• When disposal of the product, do follow 

to the precautions in #12 and comply with 
national regulations.
Always contact to local municipal offices for 
proper handling.

Safety precautions

2. Servicing
2-1. Service personnel

• Any qualified person who is involved with 

working on or breaking into a refrigerant 

circuit should hold a current valid certificate 

from an industry-accredited assessment 

authority, which authorizes their competence 

to handle refrigerants safely in accordance 

with an industry recognised assessment 

specification.

• Servicing shall only be performed 

as recommended by the equipment 

manufacturer.

Maintenance and repair requiring the 

assistance of other skilled personnel shall 

be carried out under the supervision of the 

person competent in the use of flammable 

refrigerants.

• Servicing shall be performed only as 

recommended by the manufacturer.

2-2. Work

• Prior to beginning work on systems 

containing flammable refrigerants, safety 

checks are necessary to ensure that the risk 

of ignition is minimised.

For repair to the refrigerating system, the 

precautions in #2-2 to #2-8 must be followed 

before conducting work on the system.

• Work shall be undertaken under a controlled 

procedure so as to minimize the risk of a 

flammable gas or vapour being present while 

the work is being performed.

• All maintenance staff and others working 

in the local area shall be instructed and 

supervised on the nature of work being 

carried out.

• Avoid working in confined spaces.

• Wear appropriate protective equipment, 

including respiratory protection, as 

conditions warrant.

• Ensure that the conditions within the area 

have been made safe by limit of use of any 

flammable material. Keep all sources of 

ignition and hot metal surfaces away.

2-3. Checking for presence of refrigerant

• The area shall be checked with an 

appropriate refrigerant detector prior to and 

during work, to ensure the technician is 

aware of potentially flammable atmospheres.

• Ensure that the leak detection equipment 

being used is suitable for use with flammable 

refrigerants, i.e. non sparking, adequately 

sealed or intrinsically safe.

• In case of leakage/spillage happened, 

immediately ventilate area and stay upwind 

and away from spill/release.

• In case of leakage/spillage happened, do 

notify persons down wind of the leaking/spill, 

isolate immediate hazard area and keep 

unauthorized personnel out.

ACXF55-2862̲OL.ai   6   3/3/2020   9:52:38 AM

ACXF55-2862̲OL.ai   6   3/3/2020   9:52:38 AM

Summary of Contents for CS-KU18WKYF1 Series

Page 1: ... Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference ACXF55 2862 OL ai 1 3 3 2020 9 52 34 AM ACXF55 2862 OL ai 1 3 3 2020 9 52 34 AM ...

Page 2: ...rol receiver of the indoor unit FAN DRY Operating the unit at 24 C or higher degrees may save energy Default set temperature is 24 C in COOL mode as per country guidelines ACXF55 2862 OL ai 2 3 3 2020 9 52 37 AM ACXF55 2862 OL ai 2 3 3 2020 9 52 37 AM ...

Page 3: ...10 11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 FAN CHECK MODE POWERFUL FAN SPEED AIR SWING SLEEP TEMP CLEAN DISPLAY TIMER ON OFF LOCK CANCEL 7m ACXF55 2862 OL ai 3 3 3 2020 9 52 37 AM ACXF55 2862 OL ai 3 3 3 2020 9 52 37 AM ...

Page 4: ...liances etc Refer to Table A of Installation instructions table for Amin m Be aware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handi...

Page 5: ...R410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut ...

Page 6: ...authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall b...

Page 7: ...o any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall...

Page 8: ... and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazin...

Page 9: ...tied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrig...

Page 10: ...de and room temp for FAN mode Only indoor unit fan operates as per remote settings Outdoor is OFF so no cooling achieved Provides air circulation in the room SL will be displayed on Remote The unit is turned off after 8 hours This operation provides you with a comfortable environment while sleeping by gradually increase the set temperature 1 C after 3 hours operation This operation is to achieve f...

Page 11: ...he louver swings up down automatically CL will be displayed on unit and remote controller While CL is displayed all other functions of the remote controller will be disabled except for ON OFF button Applicable for 10 to 15 minutes This feature can only be used in OFF condition CLEAN To clean dust on evap coil of the Air Conditioner Unit Select ON or OFF timer Set the time Confirm Example OFF at 14...

Page 12: ...y under shade away from fire or direct sunlight Replace any damaged filters Ag Clean Filter PM 2 5 filter Clean the filter whenever necessary Don t wash rinse the filter with water The surface of the filter shouldn t be rubbed with any object The filter shouldn t be pulled with strong force as it may get damaged Ag Clean Filter PM 2 5 filter 12 Dust filters PM2 5 Filters Ag Clean Filter ACXF55 286...

Page 13: ...The unit stops and some alpha numeric codes appear on IDU display 13 ACXF55 2862 OL ai 13 3 3 2020 9 52 41 AM ACXF55 2862 OL ai 13 3 3 2020 9 52 41 AM ...

Page 14: ...Cooling Test Mode for Full Load 100 and Half Load 50 1 Mode Select COOL 2 Temperature a 16 ºC for Full Load 100 3 Air Swing S 4 Fan speed et vane position to 3rd step from top b 17 ºC for Half Load 50 Auto OFF ON Button Indication for Half load Indication for Full load For Full Load For Half Load 14 Open the Front Panel by lifting Intake Grille Follow the below Instructions Maximum DRY FAN DRY FAN...

Page 15: ...ttp www panasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental break...

Page 16: ...here is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions ACXF55 2862 OL ai 16 3 3 2020 9 52 42 AM ACXF55 28...

Reviews: