Remote control

Do not allow infants and small children to play 
with the remote control to prevent them from 
accidentally swallowing the batteries.

Power supply

Do not use a modified cord, 
joint cord, extension cord or 
unspecified cord to prevent 
overheating and fire.

  

To prevent overheating, fire or electric shock:
• Do not share the same power outlet with 

other equipment.

• Do not operate with wet hands. 
• Do not over bend the power supply cord.
• Do not operate or stop the unit by inserting 

or pulling out the power plug.

If the supply cord is damaged, it must be 
replaced by the manufacturer, service agent 
or similarly qualified persons in order to avoid 
a hazard.
It is strongly recommended to be installed 
with Earth Leakage Circuit Breaker (ELCB) 
or Residual Current Device (RCD) to prevent 
electric shock or fire.
To prevent overheating, fire or electric shock:
• Insert the power plug properly.
• Dust on the power plug should be 

periodically wiped with a dry cloth.

Stop using the product if any abnormality/
failure occurs and disconnect the power plug 
or turn off the power switch and breaker.
(Risk of smoke/fire/electric shock) Examples 
of abnormality/failure
• The ELCB trips frequently.
• Burning smell is observed.
• Abnormal noise or vibration of the unit is 

observed.

• Water leaks from the indoor unit.
• Power cord or plug becomes abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running immediately even if it 

is switched on for operation.

• The fan does not stop even if the operation 

is stopped.

Contact your local dealer immediately for 
maintenance/repair.

This equipment must be earthed to prevent 
electrical shock or fire.

Prevent electric shock by switching off the 
power supply and unplug:
- Before cleaning or servicing,
- When extended non-use, or
- During abnormally strong lightning activity.

Precaution for using R32 refrigerant

The basic installation work procedures are the same as 
conventional refrigerant (R410A, R22) models.

Since the working pressure is higher than that of 
refrigerant R22 models, some of the piping and 
installation and service tools are special.
Especially, when replacing a refrigerant R22 
model with a new refrigerant R32 model, always 
replace the conventional piping and flare nuts 
with the R32 and R410A piping and flare nuts on 
the outdoor unit side.
For R32 and R410A, the same flare nut on the 
outdoor unit side and pipe can be used.
Models that use refrigerant R32 and R410A 
have a different charging port thread diameter to 
prevent erroneous charging with refrigerant R22 
and for safety.
Therefore, check beforehand. [The charging port 
thread diameter for R32 and R410A is 1/2 inch.]
Be more careful than R22 so that foreign matter 
(oil, water, etc.) does not enter the piping.
Also, when storing the piping, securely seal the 
opening by pinching, taping, etc. (Handling of 
R32 is similar to R410A.)

CAUTION

Indoor unit and outdoor unit

Do not wash the indoor unit with water, benzine, 
thinner or scouring powder to avoid damage or 
corrosion at the unit.
Do not use for preservation of precise 
equipment, food, animals, plants, artwork 
or other objects. This may cause quality 
deterioration, etc.
Do not use any combustible equipment in front 
of the airflow outlet to avoid fire propagation.
Do not expose plants or pet directly to airflow to 
avoid injury, etc.

Do not touch the sharp aluminium fin, 
sharp parts may cause injury.

Do not switch ON the indoor unit when waxing 
the floor. After waxing, aerate the room properly 
before operating the unit.
Do not install the unit in oily and smoky areas to 
prevent damage to the unit.
Do not dismantle the unit for cleaning purpose 
to avoid injury.
Do not step onto an unstable bench when 
cleaning the unit to avoid injury.
Do not place a vase or water container on the 
unit. Water may enter the unit and degrade the 
insulation. This may cause an electric shock.
Do not open window or door for long time during 
operation, it may lead to inefficient power usage 
and uncomfortable temperature changes.

ACXF55-2862̲OL.ai   5   3/3/2020   9:52:38 AM

ACXF55-2862̲OL.ai   5   3/3/2020   9:52:38 AM

Summary of Contents for CS-KU18WKYF1 Series

Page 1: ... Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference ACXF55 2862 OL ai 1 3 3 2020 9 52 34 AM ACXF55 2862 OL ai 1 3 3 2020 9 52 34 AM ...

Page 2: ...rol receiver of the indoor unit FAN DRY Operating the unit at 24 C or higher degrees may save energy Default set temperature is 24 C in COOL mode as per country guidelines ACXF55 2862 OL ai 2 3 3 2020 9 52 37 AM ACXF55 2862 OL ai 2 3 3 2020 9 52 37 AM ...

Page 3: ...10 11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 FAN CHECK MODE POWERFUL FAN SPEED AIR SWING SLEEP TEMP CLEAN DISPLAY TIMER ON OFF LOCK CANCEL 7m ACXF55 2862 OL ai 3 3 3 2020 9 52 37 AM ACXF55 2862 OL ai 3 3 3 2020 9 52 37 AM ...

Page 4: ...liances etc Refer to Table A of Installation instructions table for Amin m Be aware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handi...

Page 5: ...R410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut ...

Page 6: ...authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall b...

Page 7: ...o any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall...

Page 8: ... and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazin...

Page 9: ...tied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrig...

Page 10: ...de and room temp for FAN mode Only indoor unit fan operates as per remote settings Outdoor is OFF so no cooling achieved Provides air circulation in the room SL will be displayed on Remote The unit is turned off after 8 hours This operation provides you with a comfortable environment while sleeping by gradually increase the set temperature 1 C after 3 hours operation This operation is to achieve f...

Page 11: ...he louver swings up down automatically CL will be displayed on unit and remote controller While CL is displayed all other functions of the remote controller will be disabled except for ON OFF button Applicable for 10 to 15 minutes This feature can only be used in OFF condition CLEAN To clean dust on evap coil of the Air Conditioner Unit Select ON or OFF timer Set the time Confirm Example OFF at 14...

Page 12: ...y under shade away from fire or direct sunlight Replace any damaged filters Ag Clean Filter PM 2 5 filter Clean the filter whenever necessary Don t wash rinse the filter with water The surface of the filter shouldn t be rubbed with any object The filter shouldn t be pulled with strong force as it may get damaged Ag Clean Filter PM 2 5 filter 12 Dust filters PM2 5 Filters Ag Clean Filter ACXF55 286...

Page 13: ...The unit stops and some alpha numeric codes appear on IDU display 13 ACXF55 2862 OL ai 13 3 3 2020 9 52 41 AM ACXF55 2862 OL ai 13 3 3 2020 9 52 41 AM ...

Page 14: ...Cooling Test Mode for Full Load 100 and Half Load 50 1 Mode Select COOL 2 Temperature a 16 ºC for Full Load 100 3 Air Swing S 4 Fan speed et vane position to 3rd step from top b 17 ºC for Half Load 50 Auto OFF ON Button Indication for Half load Indication for Full load For Full Load For Half Load 14 Open the Front Panel by lifting Intake Grille Follow the below Instructions Maximum DRY FAN DRY FAN...

Page 15: ...ttp www panasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental break...

Page 16: ...here is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions ACXF55 2862 OL ai 16 3 3 2020 9 52 42 AM ACXF55 28...

Reviews: