background image

4

Safety precautions

To prevent personal injury, injury to others or property 
damage, please comply with the following: 
Incorrect operation due to failure to follow instructions 
below may cause harm or damage, the seriousness of 
which is classified as below:

This appliance is filled with R32 (mild 
flammable refrigerant). If the refrigerant is 
leaked and exposed to an external ignition 
source, there is a risk of fire.

WARNING

This sign warns of death 
or serious injury.

CAUTION

This sign warns of injury 
or damage to property.

The instructions to be followed are classified by the 
following symbols:

This symbol denotes an action that 
is PROHIBITED.

These symbols denote actions 

COMPULSORY.

WARNING

Indoor unit and outdoor unit

This appliance is not intended for use by 
persons (including children) with reduced 
physical, sensory or mental capabilities, or lack 
of experience and knowledge, unless they have 
been given supervision or instruction concerning 
use of the appliance by a person responsible for 
their safety. Children should be supervised to 
ensure that they do not play with the appliance.
The appliance shall be installed, and/or operated 
in a room with floor area larger than A

min

(m²) and 

keep away from ignition sources, such as heat/
sparks/open flame or hazardous areas such as 
gas appliances, gas cooking, reticulated gas 
supply systems or electric cooking appliances, etc.
(Refer to Table A of Installation instructions table 
for A

min

(m²))

Be aware that refrigerant may not contain an 
odour, highly recommended to ensure suitable 
flammable refrigerant gas detectors are present, 
operating and able to warn of a leak.
Please consult authorised dealer or specialist to 
clean the internal parts, repair, install, remove 
and reinstall the unit. Improper installation and 
handing will cause leakage, electric shock or fire.
Confirm with authorised dealer or specialist on 
usage of any specified refrigerant type. 
Using refrigerant type other than the specified 
may cause product damage, burst and injury etc.
Do not use means to accelerate the defrosting 
process or to clean, other than those 
recommended by manufacturer. Any unfit 
method or using incompatible material may 
cause product damage, burst and serious injury.
Do not pierce or burn as the appliance is 
pressurized. Do not expose the appliance to 
heat, flame, sparks, or other sources of ignition. 
Else it may explode and cause injury or death.
Do not install the unit in a potentially explosive 
or flammable atmosphere. Failure to do so could 
result in fire.
Do not insert your fingers or other objects 
into the air conditioner indoor or outdoor 
unit, rotating parts may cause injury.
Do not touch the outdoor unit during lightning, it 
may cause electric shock.
Do not expose yourself directly to cold air for a 
long period to avoid excess cooling.
Do not sit or step on the unit, you may 
fall down accidentally.

ACXF55-2751̲OL.ai   4   3/3/2020   9:50:35 AM

ACXF55-2751̲OL.ai   4   3/3/2020   9:50:35 AM

Summary of Contents for CS-KU12WKY Series

Page 1: ...es CU TU12WKY series CU TU18WKY series CU TU24WKY series ACXF55 27510 AE English Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit please read these operating instructions thoroughly and keep them for future reference ACXF55 2751 OL ai 1 3 3 2020 9 50 15 AM ACXF55 2751 OL ai 1 3 3 2020 9 50 15 AM ...

Page 2: ...rol receiver of the indoor unit FAN DRY Operating the unit at 24 C or higher degrees may save energy Default set temperature is 24 C in COOL mode as per country guidelines ACXF55 2751 OL ai 2 3 3 2020 9 50 35 AM ACXF55 2751 OL ai 2 3 3 2020 9 50 35 AM ...

Page 3: ...11 Cleaning instructions 12 Troubleshooting 13 BEE Regulation 14 Information 15 FAN CHECK MODE POWERFUL AIR SWING FAN SPEED SLEEP TEMP CLEAN DISPLAY TIMER ON OFF LOCK CANCEL SMART 7m ACXF55 2751 OL ai 3 3 3 2020 9 50 35 AM ACXF55 2751 OL ai 3 3 3 2020 9 50 35 AM ...

Page 4: ...liances etc Refer to Table A of Installation instructions table for Amin m Be aware that refrigerant may not contain an odour highly recommended to ensure suitable flammable refrigerant gas detectors are present operating and able to warn of a leak Please consult authorised dealer or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handi...

Page 5: ...R410A R22 models Since the working pressure is higher than that of refrigerant R22 models some of the piping and installation and service tools are special Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts with the R32 and R410A piping and flare nuts on the outdoor unit side For R32 and R410A the same flare nut ...

Page 6: ...authorizes their competence to handle refrigerants safely in accordance with an industry recognised assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants Servicing shall b...

Page 7: ...o any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are properly protected against being so corroded 2 8 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures Initial safety checks shall...

Page 8: ... and evacuation When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following procedure shall be adhered to remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazin...

Page 9: ...tied of refrigerant The label shall be dated and signed Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant 12 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrig...

Page 10: ...de and room temp for FAN mode Only indoor unit fan operates as per remote settings Outdoor is OFF so no cooling achieved Provides air circulation in the room SL will be displayed on Remote The unit is turned off after 8 hours This operation provides you with a comfortable environment while sleeping by gradually increase the set temperature 1 C after 3 hours operation This operation is to achieve f...

Page 11: ... start earlier up to 15 minutes before the actual set time in order to achieve the desired temperature on time ON OFF CANCEL 11 CLEAN To clean dust on evap coil of the Air Conditioner Unit To turn ON OFF Wi Fi function of Air Conditioner Unit Select ON or OFF timer Set the time Confirm Wi Fi Example OFF at 14 00 Press the OFF button OFF OFF OFF OFF OFF OFF Wait for 5 second to set timer Press OFF ...

Page 12: ...y under shade away from fire or direct sunlight Replace any damaged filters Ag Clean Filter PM 2 5 filter Clean the filter whenever necessary Don t wash rinse the filter with water The surface of the filter shouldn t be rubbed with any object The filter shouldn t be pulled with strong force as it may get damaged Ag Clean Filter PM 2 5 filter 12 Dust filters PM2 5 Filters Ag Clean Filter ACXF55 275...

Page 13: ...display Unit s Wi Fi connection with the router is activated Wi Fi LED stays ON during unit turn OFF Check unit s Wi Fi connection with router Wi Fi LED countiniuosly blinking 13 ACXF55 2751 OL ai 13 3 3 2020 9 50 39 AM ACXF55 2751 OL ai 13 3 3 2020 9 50 39 AM ...

Page 14: ...Cooling Test Mode for Full Load 100 and Half Load 50 1 Mode Select COOL 2 Temperature a 16 ºC for Full Load 100 3 Air Swing S 4 Fan speed et vane position to 3rd step from top b 17 ºC for Half Load 50 Auto OFF ON Button Indication for Half load Indication for Full load For Full Load For Half Load 14 Open the Front Panel by lifting Intake Grille Follow the below Instructions Maximum DRY FAN DRY FAN...

Page 15: ...ttp www panasonic com in corporate sustainability panasonic india i recycle program html S No 1 All electrical and electronic products are required to be handed over only to the Authorized recycler 2 The product should be handed over only to authorized recycler for disposal 3 4 5 6 Keep the product in isolated area after it becomes non functional un repairable so as to prevent its accidental break...

Page 16: ...here is a possibility of ignition This symbol shows that the Operation Instructions should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to the Installation Instructions This symbol shows that there is information included in the Operation Instructions and or Installation Instructions ACXF55 2751 OL ai 16 3 3 2020 9 50 40 AM ACXF55 27...