33
12.4. Airflow Direction Control
12.4.1.
Horizontal and Vertical Directions
Vertical louver is controlled by remote control: the Vertical Airflow Direction button on the remote controller and by each operation
mode, as shown in the table below.
Cooling Operation Mode
Manual Operation
Vertical Automatic Operation
Powerful-ON
• Five-level setting is possible with the remote
controller.
• The louver swings between the upper limit
and the lower limit.
• After Powerful is turned on, the louver is
fixed at 26
°
for 5 minutes or until the Neural
Control is stabilized.
• After the Neural Control is stabilized, the
louver is fixed at 12
°
.
Dry Operation Mode
Manual Operation
Vertical Automatic Operation
Power-ON (Automatic Operation)
• Five-level setting is possible with the remote
controller.
• The louver is fixed at 12
°
.
• The louver is fixed at 12
°
.