background image

6

   CARE & CLEANING

  CARE & CLEANING

   e-ion FILTERS

  

e-ion 

FILTERS

 

Switch off the power supply before cleaning.

 

Do not touch the aluminium 

fi

 n, sharp part may cause injury.

• Clean the 

fi

 lters regularly.

• Wash/rinse the 

fi

 lters gently with water 

to avoid damage to the 

fi

 lter surface.

• Dry the 

fi

 lters thoroughly under 

the shade, away from 

fi

 re or direct 

sunlight.

•  Replace any damage 

fi

 lter. 

ACTIVE e-ion GENERATOR

ACTIVE e-ion GENERATOR

FRONT PANEL

FRONT PANEL

Raise and pull to remove. Wash 

gently and dry.

Remove

Remove

WASHING  INSTRUCTIONS

WASHING  INSTRUCTIONS

•  Do not use benzene, thinner or scouring powder.
•  Use only soap (  pH7) or neutral household detergent.
•  Do not use water hotter than 40°C.

ACTIVE e-ion POWER MODULE

ACTIVE e-ion POWER MODULE

Clean with dry cotton bud.

• Active e-ion generator 

cleaning is recommended 

every 6 months.

INDOOR UNIT

INDOOR UNIT

Wipe the unit gently with a soft, 

dry cloth.

  HINTS

 HINTS

• Clean the 

fi

 lter regularly for best performance and to 

reduce power consumption.

•  Please consult your nearest dealer for seasonal 

inspection.

ALUMINIUM FIN

ALUMINIUM FIN

CAUTION

FOR SEASONAL INSPECTION AFTER EXTENDED 

FOR SEASONAL INSPECTION AFTER EXTENDED 
NON-USE

NON-USE

•  Checking of remote control batteries.
•  No obstruction at air inlet and air outlet vents.
•  After 15 minutes of operation, it is normal to have the 

following temperature difference between air inlet and air 

outlet vents: 

Cooling: 

 8°C  

Heating:  

 14°C

NON SERVICEABLE CRITERIAS

NON SERVICEABLE CRITERIAS

TURN OFF POWER SUPPLY then CALL Authorized 

Distributor under the following conditions:
•  Abnormal noise during operation.
•  Water/foreign particles have entered the remote control.
•  Water leaks from Indoor unit.
•  Circuit breaker switches off frequently.
•  Power cord becomes unnaturally warm.
•  Switches or buttons are not functioning properly.

FOR EXTENDED NON-USE

FOR EXTENDED NON-USE

•  Activate heat mode for 2~3 hours to remove moisture left in 

the internal parts thoroughly.

•  Turn off the power supply.
•  Remove the remote control batteries.

Summary of Contents for CS-E18HKR

Page 1: ...nasonic HA Air Conditioning M Sdn Bhd 11969 T All rights reserved Unauthorized copying and distribution is a violation of law QUICK GUIDE QUICK GUIDE Before operating the unit read these operating instructions thoroughly and keep them for future reference Before operating the unit read these operating instructions thoroughly and keep them for future reference ...

Page 2: ...epair the unit by yourself Indoor Unit Do not install the unit in a potentially explosive atmosphere Do not wash the unit with water benzene thinner or scouring powder Do not use for other purposes such as preservation of food Do not use any combustible equipment in front of the airflow outlet Do not expose directly to cold air for a long period Ensure that the drainage pipe is connected properly ...

Page 3: ...reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Information for Users on Collection and Disposal of Old Equipment and used Batteries Information on Disposa...

Page 4: ...te control display INDICATOR TO TURN ON OR OFF THE UNIT Please be aware of the OFF indication on the remote control display to prevent the unit from starting stopping improperly TO SET TEMPERATURE Selection range 16 C 30 C Operating the unit within the recommended temperature could induce energy saving HEAT mode 20 C 24 C COOL mode 26 C 28 C DRY mode 1 C 2 C lower than room temperature TO SELECT O...

Page 5: ...E TEMPERATURE QUICKLY To turn ON or OFF the unit at a preset time Select ON or OFF timer Set the time Confirm To cancel ON or OFF timer press or then press When ON Timer is set the unit may start earlier up to 30 minutes before the actual set time in order to achieve the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock...

Page 6: ...HINTS Clean the filter regularly for best performance and to reduce power consumption Please consult your nearest dealer for seasonal inspection ALUMINIUM FIN ALUMINIUM FIN CAUTION FOR SEASONAL INSPECTION AFTER EXTENDED FOR SEASONAL INSPECTION AFTER EXTENDED NON USE NON USE Checking of remote control batteries No obstruction at air inlet and air outlet vents After 15 minutes of operation it is nor...

Page 7: ... stops occasionally during automatic fan speed setting This helps to remove the surrounding odours Operation is delayed a few minutes after restart The delay is a protection to the unit s compressor Outdoor unit emits water steam Condensation or evaporation occurs on pipes Timer indicator is always on The timer setting repeats daily once set Power indicator blinks during operation and the indoor f...

Page 8: ...WERFUL QUIET MODE FAN SPEED SET ON CANCEL OFF AIR SWING Remote Control Preparation Remote Control Preparation Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global F566113 Printed in Malaysia OPTK0803 00 QUICK GUIDE QUICK GUIDE 1 Press and pull out 2 Insert AAA or R03 batteries can be used 1 year 3 Press CLOCK 4 Set time 5 Confirm 6 Close the cover ...

Reviews: