background image

5

  TO SET THE TIMER

  TO SET THE TIMER

• 

 and 

 can be activated 

in all modes and can be cancelled by pressing the 

respective button again.

• 

 and 

 or 

 and 

  can not 

be activated at the same time.

• 

 and 

 can be activated even when the 

unit is turned off. In this condition, once e-ion indicator 

is ON, the unit will operate with AUTO fan speed and 

air swing.

TO SELECT FAN SPEED 

(5 OPTIONS)

•  For AUTO, the indoor fan speed is automatically 

adjusted according to the operation mode.

AIR SWING

TO ADJUST AIRFLOW DIRECTION  

(5 OPTIONS)

   

   

•  Keeps the room ventilated.

•  If AUTO is set, the louvers swing left/right and 

up/down automatically.

•  In heat mode, the air blows horizontally for a while, 

then starts to blow downwards and the air

fl

 ow louvers 

start to swing left/right after the temperature rises.

TO MONITOR AIR QUALITY

•  Patrol sensor detects air quality.

•  When air quality is unsatisfactory, e-ion operation will 

start automatically.

TO ENJOY CLEAN & FRESH AIR

•  Generates negative ions to produce fresh air effect 

and attract dust which will then be captured at the 

positively charged e-ion 

fi

 lters.

TO ENJOY QUIET ENVIRONMENT

•  This operation reduces air

fl

 ow noise.

TO ACHIEVE TEMPERATURE 

QUICKLY

•  To turn ON or OFF the unit at a preset time.

Select ON or 

OFF timer.

Set the time.

Con

fi

 rm.

•  To cancel ON or OFF timer, press 

 or 

 then 

press 

.

•  When ON Timer is set, the unit may start earlier (up 

to 30 minutes) before the actual set time in order to 
achieve the desired temperature on time.

•  Timer operation is based on the clock set in the remote 

control and repeats daily once set. For clock setting,  
please refer to Remote Control Preparation at back 
cover.

•  If timer is cancelled manually or due to power failure, 

you can restore the previous setting (once power is 
resumed) by pressing 

.

  OPTIONAL SETTINGS

 OPTIONAL 

SETTINGS

Patrol starts automatically with the unit 
switched on with 

.

Press and hold for 5 seconds, then release 
to disable or restore this setting.

Press and hold for 5 seconds to dim or 
restore the unit’s indicator brightness.

Press and hold for approximately 10 
seconds to show temperature setting in 
°C or °F.

Press and hold for approximately 5 seconds 
to show 12-hour (am/pm) or 24-hour time 
indication.

 

Press to restore the remote control’s default 

setting.

 , 

  Not used in normal operations.

Set the temperature 1°C higher in cool mode or 2°C 
lower in heat mode than the desired temperature to 
achieve a 10% power saving.

Use curtains to screen off sunlight and outdoor heat to 
reduce power consumption during cool mode.

Summary of Contents for CS-E18HKR

Page 1: ...nasonic HA Air Conditioning M Sdn Bhd 11969 T All rights reserved Unauthorized copying and distribution is a violation of law QUICK GUIDE QUICK GUIDE Before operating the unit read these operating instructions thoroughly and keep them for future reference Before operating the unit read these operating instructions thoroughly and keep them for future reference ...

Page 2: ...epair the unit by yourself Indoor Unit Do not install the unit in a potentially explosive atmosphere Do not wash the unit with water benzene thinner or scouring powder Do not use for other purposes such as preservation of food Do not use any combustible equipment in front of the airflow outlet Do not expose directly to cold air for a long period Ensure that the drainage pipe is connected properly ...

Page 3: ...reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Information for Users on Collection and Disposal of Old Equipment and used Batteries Information on Disposa...

Page 4: ...te control display INDICATOR TO TURN ON OR OFF THE UNIT Please be aware of the OFF indication on the remote control display to prevent the unit from starting stopping improperly TO SET TEMPERATURE Selection range 16 C 30 C Operating the unit within the recommended temperature could induce energy saving HEAT mode 20 C 24 C COOL mode 26 C 28 C DRY mode 1 C 2 C lower than room temperature TO SELECT O...

Page 5: ...E TEMPERATURE QUICKLY To turn ON or OFF the unit at a preset time Select ON or OFF timer Set the time Confirm To cancel ON or OFF timer press or then press When ON Timer is set the unit may start earlier up to 30 minutes before the actual set time in order to achieve the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock...

Page 6: ...HINTS Clean the filter regularly for best performance and to reduce power consumption Please consult your nearest dealer for seasonal inspection ALUMINIUM FIN ALUMINIUM FIN CAUTION FOR SEASONAL INSPECTION AFTER EXTENDED FOR SEASONAL INSPECTION AFTER EXTENDED NON USE NON USE Checking of remote control batteries No obstruction at air inlet and air outlet vents After 15 minutes of operation it is nor...

Page 7: ... stops occasionally during automatic fan speed setting This helps to remove the surrounding odours Operation is delayed a few minutes after restart The delay is a protection to the unit s compressor Outdoor unit emits water steam Condensation or evaporation occurs on pipes Timer indicator is always on The timer setting repeats daily once set Power indicator blinks during operation and the indoor f...

Page 8: ...WERFUL QUIET MODE FAN SPEED SET ON CANCEL OFF AIR SWING Remote Control Preparation Remote Control Preparation Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global F566113 Printed in Malaysia OPTK0803 00 QUICK GUIDE QUICK GUIDE 1 Press and pull out 2 Insert AAA or R03 batteries can be used 1 year 3 Press CLOCK 4 Set time 5 Confirm 6 Close the cover ...

Reviews: