17
Indoor CS-E18NKEW,
CS-XE18NKEW CS-E21NKEW,
CS-XE21NKEW
Model
Outdoor CU-E18NKE
CU-E21NKE
Performance Test Condition
EUROVENT
EUROVENT
Phase, Hz
Single, 50
Single, 50
Power Supply
V 230
230
Min. Mid. Max. Min. Mid. Max.
kW
0.98 5.00 6.00 0.98 6.30 7.10
BTU/h
3340 17100 20500 3340 21500 24200
Capacity
Kcal/h
840 4300 5160 840 5420 6110
Running
Current
A
- 6.6 - - 9.9 -
Input
Power
W
280 1.47k 2.03k 280 2.21k 2.54k
Annual
Consumption kWh
- 735 - - 1105 -
W/W
3.50 3.40 2.96 3.50 2.85 2.80
BTU/hW 11.93 11.63 10.10 11.93 9.73 9.53
EER
Kcal/hW 3.00 2.93 2.54 3.00 2.45 2.41
Power
Factor
%
- 97 - - 97 -
dB-A
44 / 37 / 34
45 / 37 / 34
Indoor Noise (H / L / QLo)
Power Level dB
60 / -
61 / -
dB-A
47 / -
48 / -
Cooling
Outdoor Noise (H / L)
Power Level dB
61 / -
62 / -
kW
0.98 5.80 8.00 0.98 7.20 8.50
BTU/h
3340 19800 27300 3340 24600 29000
Capacity
Kcal/h
840 4990 6880 840 6190 7310
Running
Current
A
- 6.9 - - 9.4 -
Input
Power
W
340 1.54k 2.60k 340 2.10k 2.75k
W/W
2.88 3.77 3.08 2.88 3.43 3.09
BTU/hW 9.82 12.86 10.50 9.82 11.71 10.55
COP
Kcal/hW 2.47 3.24 2.65 2.47 2.95 2.66
Power
Factor
%
- 97 - - 97 -
dB-A
44 / 37 / 34
45 / 37 / 34
Indoor Noise (H / L / QLo)
Power Level dB
60 / -
61 / -
dB-A
47 / -
49 / -
Heating
Outdoor Noise (H / L)
Power Level dB
61 / -
63 / -
Low Temp. : Capacity (kW) / I.Power (W) / COP
5.80 / 2.35k / 2.47
6.16 / 2.43k / 2.53
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
4.98 / 2.41k / 2.07
5.24 / 2.54k / 2.06
Max Current (A) / Max Input Power (W)
11.4 / 2.60k
12.1 / 2.75k
Starting Current (A)
6.9
9.9
Type
Hermetic Motor (Rotary)
Hermetic Motor (Rotary)
Motor Type
Brushless (4-poles) Brushless
(4-poles)
Compressor
Output Power
W
900
900
Summary of Contents for CS-E12NKEW
Page 21: ...21 Outdoor Unit CU 2E15LBE Outdoor Unit CU 2E18LBE ...
Page 22: ...22 Outdoor Unit CU 3E18LBE ...
Page 23: ...23 Outdoor Unit CU 4E23LBE ...
Page 24: ...24 ...
Page 25: ...25 Outdoor Unit CU 4E27CBPG ...
Page 26: ...26 ...
Page 28: ...28 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 30: ...30 5 1 2 CS E18NK CS E21NK CS XE18NK CS XE21NK ...
Page 32: ...32 5 2 3 CU E18NKE CU E21NKE ...
Page 33: ...33 6 Refrigeration Cycle Diagram 6 1 CU E7NKE CU E9NKE CU E12NKE CU E15NKE ...
Page 34: ...34 6 2 CU E7NKE 3 CU E9NKE 3 CU E12NKE 3 ...
Page 35: ...35 6 3 CU E18NKE ...
Page 36: ...36 6 4 CU E21NKE ...
Page 37: ...37 7 Block Diagram 7 1 CU E7NKE CU E9NKE ...
Page 38: ...38 7 2 CU E12NKE ...
Page 39: ...39 7 3 CU E15NKE ...
Page 40: ...40 7 4 CU E7NKE 3 CU E9NKE 3 CU E12NKE 3 ...
Page 41: ...41 7 5 CU E18NKE CU E21NKE ...
Page 42: ...42 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 43: ...43 8 2 Outdoor Unit 8 2 1 CU E7NKE CU E9NKE ...
Page 44: ...44 8 2 2 CU E12NKE ...
Page 45: ...45 8 2 3 CU E15NKE ...
Page 46: ...46 8 2 4 CU E7NKE 3 CU E9NKE 3 CU E12NKE 3 ...
Page 47: ...47 8 2 5 CU E18NKE CU E21NKE ...
Page 48: ...48 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 49: ...49 9 2 Outdoor Unit 9 2 1 CU E7NKE CU E9NKE ...
Page 50: ...50 9 2 2 CU E12NKE ...
Page 51: ...51 9 2 3 CU E15NKE ...
Page 52: ...52 9 2 4 CU E7NKE 3 CU E9NKE 3 CU E12NKE 3 ...
Page 53: ...53 9 2 5 CU E18NKE CU E21NKE ...
Page 54: ...54 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 56: ...56 10 1 5 Human Activity Sensor Printed Circuit Board ...
Page 57: ...57 10 2 Outdoor Unit 10 2 1 CU E7NKE CU E9NKE CU E7NKE 3 CU E9NKE 3 CU E12NKE 3 ...
Page 58: ...58 10 2 2 CU E12NKE CU E15NKE ...
Page 59: ...59 10 2 3 CU E18NKE CU E21NKE ...
Page 96: ...96 16 3 Error Codes Table ...
Page 97: ...97 ...
Page 127: ...127 17 1 1 3 To remove discharge grille ...
Page 128: ...128 17 1 1 4 To remove control board 17 1 1 5 To remove cross flow fan and indoor fan motor ...
Page 129: ...129 ...
Page 131: ...131 17 2 1 3 To remove power electronic controller ...
Page 133: ...133 ...