background image

4

MULTI AIR CONDITIONER SYSTEM

Multi Split Outdoor Unit
(CU-2E18JBK)

DEFINITION

Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit.

Living room

Living room

Multi Split Outdoor Unit

Multi Split Outdoor Unit

INDOOR UNIT

INDOOR UNIT

• It is possible to operate the indoor units individually or simultaneously. The operation mode priority is given to the fi rst unit 

that turned on.

• During operation, heating and cooling mode could not be activated at the same time for different indoor unit. The power 

indicator blinks to indicate the indoor unit is standing by for different operation mode.

Bedroom

Bedroom

POWER SUPPLY

POWER SUPPLY

Models Number

Time Delay Circuit

Breaker

Rated Volts

Single Split System

CS-E9JKKW / CU-E9JKK

15 Amps

208/230V

CS-E12JKKW / CU-E12JKK

15 Amps

CS-E18JKK / CU-E18JKK

20 Amps

CS-E22JKK / CU-E22JKK

25 Amps

Multi Split System

CS-E9JKKW, CS-E9JKKW / CU-2E18JBK

25 Amps

208/230V

CS-E9JKKW, CS-E12JKKW / CU-2E18JBK
CS-E12JKKW, CS-E12JKKW / CU-2E18JBK

Summary of Contents for CS-E12JKKW

Page 1: ...em for future reference FRANÇAIS 11 19 Avant d utiliser le climatiseur lire ces instructions d utilisation et les conserver pour s y référer dans le futur QUICK GUIDE QUICK GUIDE GUIDE SOMMAIRE GUIDE SOMMAIRE Operating Instructions Air Conditioner Model No Indoor Unit Single Split Outdoor Unit CS E9JKKW CU E9JKK CS E12JKKW CU E12JKK CS E18JKK CU E18JKK CS E22JKK CU E22JKK Multi Split Outdoor Unit ...

Page 2: ...Improper installation and handling will cause leakage electric shock or fire Do not install the unit in a potentially explosive or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Do not touch the outdoor unit during lightning it may cause electric shock REMOTE CONT...

Page 3: ...riod of time New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control WARNING WARNING POWER SUPPLY Do not use modified cord joint cord extension cord or unspecified cord to prevent overheating and fire Do not share the same power outlet with other equipment to prevent overheating and fire Do not operate with wet hands to prevent ele...

Page 4: ...he first unit that turned on During operation heating and cooling mode could not be activated at the same time for different indoor unit The power indicator blinks to indicate the indoor unit is standing by for different operation mode Bedroom Bedroom POWER SUPPLY POWER SUPPLY Models Number Time Delay Circuit Breaker Rated Volts Single Split System CS E9JKKW CU E9JKK 15 Amps 208 230V CS E12JKKW CU...

Page 5: ...curely 3 REMOTE CONTROL RECEIVER 4 ALUMINIUM FIN 5 HORIZONTAL AIRFLOW DIRECTION LOUVER E9JKKW E12JKKW Manually adjustable E18JKK E22JKK Do not adjust by hand 6 VERTICAL AIRFLOW DIRECTION LOUVER Do not adjust by hand 7 AUTO OFF ON BUTTON Use when remote control is misplaced or a malfunction occurs Action Mode Press once Auto Press and hold until 1 beep is heard then release Cooling Press and hold u...

Page 6: ...ing stopping improperly 2 TO SET TEMPERATURE Selection range 16 C 30 C Operating the unit within the recommended temperature could induce energy saving HEAT mode 20 C 24 C COOL mode 26 C 28 C DRY mode 1 C 2 C lower than room temperature 3 TO SELECT OPERATION MODE AUTO mode For your convenience During operation mode selection the power indicator blinks Unit selects operation mode every 30 minutes a...

Page 7: ... in all modes and can be cancelled by pressing the respective button again QUIET POWERFUL Cannot be selected at the same time TO SET THE TIMER TO SET THE TIMER To turn ON or OFF the unit at a preset time ON OFF 1 2 SET Select ON or OFF timer Set the time Confirm To cancel ON or OFF timer press ON or OFF then press CANCEL When ON Timer is set the unit may start earlier up to 35 minutes before the a...

Page 8: ...en the ON timer has been set Cracking sound during operation Changes of temperature cause the expansion contraction of the unit Check the following before calling for servicing Check the following before calling for servicing SYMPTOM SYMPTOM CHECK CHECK Heating Cooling operation is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear ...

Page 9: ...the internal parts thoroughly to prevent mould growth Turn off the power supply Remove the remote control batteries SERVICEABLE CRITERIAS TURN OFF POWER SUPPLY then please consult authorized dealer under the following conditions Abnormal noise during operation Water foreign particles have entered the remote control Water leaks from Indoor unit Circuit breaker switches off frequently Power cord bec...

Page 10: ...n hors marche 2 TEMP TEMP Select the desired temperature Régler la température souhaitée 3 Panasonic Corporation Site Web http panasonic net Panasonic Canada Inc Site Web http www panasonic ca Imprimé en Malaisie OSTH0907 00 F567333 Remote Control Preparation Préparation de la télécommande Remote Control Preparation Préparation de la télécommande 1 2 3 TIMER SET CANCEL ON OFF 1 2 3 SET CHECK CLOCK...