CARE & CLEANING

Vacuum, wash and dry.

AIR FILTER

AIR FILTER

SUPERSONIC AIR 

SUPERSONIC AIR 

PURIFYING DEVICE

PURIFYING DEVICE

INDOOR UNIT

INDOOR UNIT

Wipe gently.

Remove

Remove

Raise and pull to remove. 
Wash and dry.

FRONT PANEL

FRONT PANEL

 

Washing Instructions

•  Do not use benzene, thinner or 

scouring powder.

•  Use only soaps (

pH7) or neutral 

household detergent.

•  Do not use water hotter than 40°C.

INDOOR UNIT

AIR FILTER

•  Wipe the unit gently with a soft, dry 

cloth.

• Air 

fi

 lters cleaning is needed every 

two weeks.

•  Replace any damaged 

fi

 lter.

Part no.: CWD001144

 

Hints

•  

Clean the 

fi

 lter regularly for best 

performance and to reduce power 
consumption. 

•   Please consult your nearest dealer 

for seasonal inspection.

•  It is recommended to vacuum the

fi

 lters every 6 months.

•  For best perfomance, place the 

deodorizing 

fi

 lter under direct 

sunlight for at least six hours every 
six months.

• Replace the 

fi

 lter every 3 years or 

replace any damaged 

fi

 lters.

  Part no: CZ-SAD13P

SUPER ALLERU-BUSTER AND 

DEODORIZING FILTERS

 

For extended non-use

•  Activate heating for 2~3 hours to thoroughly dry the unit.
•  Turn off the power supply.
•  Remove the remote control batteries.

Vacuum, wash and 
dry the frame.

Remove

Vacuum the super 
alleru-buster 

fi

 lter.

Vacuum the deodorizing 

fi

 lter and place under 

direct sunlight.

Summary of Contents for CS-E12FKR

Page 1: ...ead these operating instructions thoroughly and keep them for future reference Manufactured by Panasonic HA Air Conditioning M Sdn Bhd Lot 2 Persiaran Tengku Ampuan Section 21 Shah Alam Industrial Site 40300 Shah Alam Selangor Malaysia 2006 Panasonic HA Air Conditioning M Sdn Bhd 11969 T All rights reserved Unauthorized copying and distribution is a violation of law ...

Page 2: ...d small children to play with the remote control to prevent them from accidentally swallowing the batteries Do not install remove and reinstall the unit by yourself improper installation will cause leakage electric shock or fire Please consult an authorized dealer or specialist for the installation work This equipment must be earthed and installed with ELCB It may cause electrical shock or fire in...

Page 3: ...oduct please contact your installer dealer or local authority and ask for the correct method of disposal E Environmental Requirements nvironmental Requirements End of Life Disposal End of Life Disposal The appliance is not intended for use by young children or the infirm person without supervision Young children should be supervised to ensure that they do not play with the appliance Use this air c...

Page 4: ... Automatic Press and hold until you hear one beep then release Cooling Press until you hear one beep then release Press again until you hear two beeps then release Heating To turn off press the AUTO OFF ON button again In the event of an error the unit will stop and the timer indicator will blink 2 Press until you hear beep sound then jot down the error code Notes The unit may be operable with 4 b...

Page 5: ...set correctly Make sure windows and doors are closed Make sure filters are cleaned and replaced Make sure inlet and outlet vents are cleared Water flowing sound during operations Cause by refrigerant flow inside the unit The power indicator blinks during the operation and the indoor fan is stopped The unit is in defrost mode and the melted frost is drained from the outdoor unit Operation Details C...

Page 6: ...g Indoor fan stops occasionally during automatic fan speed setting This helps to remove the surrounding odours Indoor fan stops occasionally during heating operation To avoid unintended cooling effect If automatic vertical airflow direction has been set the louvers swing up and down automatically For HEATING operation the air blows horizontally for a while then starts to blow downwards Keeps the r...

Page 7: ...les powerful operation POWERFUL Hint To reduce power consumption during cooling operation close the curtains to prevent the sunlight and heat from coming in Operation Details To reach the desired set temperature quickly POWERFUL To provide a quiet surrounding QUIET Troubleshooting Noisy during operation The unit may have been installed at an incline or the front panel is not closed properly Operat...

Page 8: ...en set The set timer repeats daily once set If there is a power failure you can restore the previous setting once power is resumed by pressing the SET button If the timer is cancelled press SET to restore the previous setting Hints Press and hold the CLOCK for approximately 5 seconds to set either 12 hour am pm or 24 hour time indication To dim the indicator display To switch the temperature setti...

Page 9: ...d every two weeks Replace any damaged filter Part no CWD001144 Hints Clean the filter regularly for best performance and to reduce power consumption Please consult your nearest dealer for seasonal inspection It is recommended to vacuum the filters every 6 months For best perfomance place the deodorizing filter under direct sunlight for at least six hours every six months Replace the filter every 3...

Page 10: ...NDED NON USE Checking of remote control batteries No obstruction at inlet and outlet vents After 15 minutes of operation it is normal to have the following temperature difference between inlet and outlet vents Cooling 8 C Heating 14 C ...

Page 11: ... conditions Abnormal noise during operation Circuit breaker switches off frequently Water foreign particles have entered the Remote Control Power cord becomes unnaturally warm Water leak from Indoor unit Switches or buttons are not functioning properly NON SERVICEABLE CRITERIAS ...

Page 12: ...Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global F565371 Printed in Malaysia OPSC0606 01 ...

Reviews: