![Panasonic CS/CU-HU12AKY Series Operating & Installation Instructions Manual Download Page 18](http://html1.mh-extra.com/html/panasonic/cs-cu-hu12aky-series/cs-cu-hu12aky-series_operating-and-installation-instructions-manual_4710140018.webp)
18
How to Fix Installation Plate
To Drill a Hole in the wall and install a sleeve of piping
Installation instructions
Indoor Unit
The mounting wall shall be strong and solid enough to prevent it from vibration.
Model
Dimension
HU12 Series, XU12 Series,
AU12 Series
HU18 Series, XU18 Series,
AU18 Series, AU24 Series.
490 mm
590 mm
82 mm
82 mm
439 mm
539 mm
432 mm
532 mm
43 mm
169 mm
95 mm
219 mm
3
4
5
6
Wall
Wall
Wall
Installation plate
screw
More than
More than
Indoor unit
241.5 mm
128 mm
241.5 mm
128 mm
128 mm
More than
For best strength of INDOOR
unit installation, it is highly
recommended to locate “ ”
at 5 position as shown.
Measuring
Tape
The center of installation plate should be at more than at right and left of the wall.
The distance from installation plate edge to ceiling should more than .
From installation plate center to unit’s left side is .
From installation plate center to unit’s right side is .
: For left side piping, piping connection for liquid should be about from this line.
: For left side piping, piping connection for gas should be about from this line.
1 Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts).
• Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
a level gauge.
2 Drill the piping plate hole with ø70 mm hole-core drill.
• Line according to the left and right side of the installation plate.
The meeting point of the extended line is the center of the hole.
Another method is by putting measuring tape at position as shown in the diagram above.
The hole center is obtained by measuring the distance namely 128 mm for left and right hole respectively.
• Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor side.
①
②
③
④
○
B
⑤
⑥
1 Insert the piping sleeve to the hole.
2 Fix the bushing to the sleeve.
3 Cut the sleeve until it extrudes
about 15 mm from the wall.
4 Finish by sealing the sleeve with putty
or caulking compound at the final stage.
15 mm
Putty or caulking
compound
ø70 mm
through
hole
Indoor
Outdoor
Sleeve
for tube
assembly
Approx.
5 - 7 mm
Bushing
for tube
assembly
Wall
CAUTION
When the wall is hollow, please be
sure to use the sleeve for tube
assembly to prevent dangers caused
by mice biting the connection cable.