- If piping length is over the common length, additional refrigerant
should be added as shown in the table.
Piping
size
Common
Length
(m)
Max.
Elevation
(m)
Max.
Piping
Length
(m)
Additional
Refrigerant
(g/m)
Model
GasLiquid
C9BKNG 3/8” 1/4”
7.5
5
10
10
C12BKNG 1/2” 1/4”
7.5
5
15
10
Indoor/Outdoor Unit Installation Diagram