33
12.7. Horizontal Airflow Direction Control
12.7.1.
Auto Control
• When the horizontal airflow direction is set to Auto using the remote control, the vanes swings left and right as shown in the
diagram.
• When stopped with remote control, the discharge vane is reset, and stop at the reset position.
• During Cooling operation or Soft Dry operation, indoor fan motor may stop to rotate at certain periods. At that condition, the vane
will stop swinging and rest at 22
q
angle.
12.7.2.
Manual Control
• When the horizontal airflow direction is set to Manual using the remote control, the automatic airflow is released and the airflow
direction vane move left and right in the range shown in the diagram.
The louver can be adjusted by pressing the button to the desired vane position.
• When stopped with remote control, the vanes is reset, and stopped at reset position.
12.8. Powerful Operation
• To achieve the setting temperature quickly.
• When Powerful operation is set, the setting temperature will be automatically decreased 3
q
C internally against the present
setting temperature (Lower temperature limit: 16
q
C).
• This operation automatically will be running under SHi Fan Speed (Cooling).
• Vertical Airflow Direction:-
- In “Manual” setting, the vane will automatically shift down 10
q
lower than previous setting.
- In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10
q
downward.
• Powerful operation stops when:-
• Powerful operation has operate for 15 minutes.
• Powerful button is pressed again.
• Quiet button is pressed.
• Stopped by OFF/ON operation button.
• Timer OFF activates.
• Operation mode is changed.
Summary of Contents for CS-C18HKD
Page 9: ...9 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 10: ...10 5 Dimensions 5 1 Indoor Unit Remote Control 5 1 1 CS C18HKD CS C24HKD ...
Page 11: ...11 5 2 Outdoor Unit 5 2 1 CU C18HKD 5 2 2 CU C24HKD ...
Page 12: ...12 6 Refrigeration Cycle Diagram ...
Page 13: ...13 7 Block Diagram ...
Page 16: ...16 9 Electronic Circuit Diagram ...
Page 17: ...17 10 Printed Circuit Board 10 1 Indoor Unit Main Printed Circuit Board TOP VIEW ...
Page 18: ...18 BOTTOM VIEW ...
Page 19: ...19 10 2 Indoor Unit Power Printed Circuit Board ...
Page 20: ...20 10 3 Indicator panel TOP VIEW BOTTOM VIEW ...
Page 49: ...49 ...
Page 50: ...50 ...
Page 51: ...51 ...
Page 52: ...52 ...
Page 53: ...53 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...
Page 54: ...54 17 2 Operation Characteristics 17 2 1 CS C18HKD CU C18HKD ...
Page 55: ...55 ...
Page 56: ...56 17 2 2 CS C24HKD CU C24HKD ...
Page 57: ...57 ...