10 Installation Instructions
Required tools for Installation Works
1. Philips screw driver
5. Spanner
9. Gas leak detector
13. Multimeter
2. Level gauge
6. Pipe cutter
10. Measuring tape
14. Gauge manifold
3. Electric drill, hole core drill
(ø70 mm)
7. Reamer
11. Thermometer
15. Torque wrench
18 N.m (1.8 kgf.m)
55 N.m (5.5 kgf.m)
65 N.m (6.5 kgf.m)
4. Hexagonal wrench (4 mm) 8. Knife
12. Megameter
10.1. Safety Precautions
•
Read the following “SAFETY PRECAUTIONS” carefully before installation.
•
Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit
for the model to be installed.
•
The caution items stated here must be followed because these important contents are related to safety. The meaning of each
indication used is as below. Incorrect installation due to ignoring of the instruction will cause harm or damage, and the
seriousness is classified by the following indications.
This indication shows the possibility of causing death or serious injury.
This indication shows the possibility of causing injury or damage to properties only.
The items to be followed are classified by the symbols:
Symbol with background white denotes item that is PROHIBITED from doing.
•
Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and
maintenance as stated in instructions. Please remind the customer to keep the operating instructions for future reference.
1. Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fire.
2. Install according to this installation instruction strictly. If installation is defective, it will cause water leakage, electrical shock or fire.
3. Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fire or
electrical shock.
4. Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation is not properly
done, the set will drop and cause injury.
5. For electrical work, follow the local national wiring standard, regulation and this installation instructions. An independent circuit and single
outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fire.
6. Use the specified cable (2.5 mm
2
) and connect tightly for indoor/outdoor connection. Connect tightly and clamp the cable so that no
external force will be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
7. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed perfectly, it will
cause heat-up at connection point of terminal, fire or electrical shock.
8. When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into refrigeration cycle.
Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion and injury.
9. Do not damage or use unspecified power supply cord. Otherwise, it will cause fire or electrical shock.
10. Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with
other electrical appliances. Otherwise, it will cause fire or electrical shock.
35
CS-C18DKD CU-C18DKD / CS-C24DKD CU-C24DKD
Summary of Contents for CS-C18DKD
Page 11: ...4 2 Outdoor Unit 4 2 1 CU C18DKD 11 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Page 12: ...4 2 2 CU C24DKD 12 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Page 13: ...5 Refrigeration Cycle Diagram 13 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Page 14: ...6 Block Diagram 14 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Page 15: ...7 Wiring Diagram CS C18DKD CU C18DKD CS C24DKD CU C24DKD 15 ...
Page 16: ...CS C18DKD CU C18DKD CS C24DKD CU C24DKD 16 ...
Page 29: ...9 Operating Instructions 29 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Page 30: ...30 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Page 31: ...31 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Page 32: ...32 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Page 33: ...33 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Page 34: ...34 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Page 39: ...3 For the embedded piping 39 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Page 59: ...59 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...
Page 70: ...19 2 Remote Control 70 CS C18DKD CU C18DKD CS C24DKD CU C24DKD ...