background image

4

Safety precautions

To prevent personal injury, injury to others 
or property damage, please comply with the 
following: 
Incorrect operation due to failure to follow 
instructions below may cause harm or damage, 
the seriousness of which is classi

fi

 ed as below:

WARNING

This sign warns of 
death or serious 
injury.

CAUTION

This sign warns of 
injury or damage to 
property.

The instructions to be followed are classi

fi

 ed by 

the following symbols:

This symbol denotes an 
action that is PROHIBITED.

These symbols denote 
actions COMPULSORY.

  

WARNING

Indoor unit and outdoor unit

This appliance is not intended for use by 

persons (including children) with reduced 

physical, sensory or mental capabilities, or lack 

of experience and knowledge, unless they have 

been given supervision or instruction concerning 

use of the appliance by a person responsible for 

their safety. Children should be supervised to 

ensure that they do not play with the appliance.
Please consult authorised dealer or specialist to 

clean the internal parts, repair, install, remove 

and reinstall the unit. Improper installation and 

handling will cause leakage, electric shock or 

fi

 re.

Con

fi

 rm with authorised dealer or specialist on 

usage of any speci

fi

 ed refrigerant type. 

Using refrigerant type other than the speci

fi

 ed 

may cause product damage, burst and injury etc.
Do not install the unit in a potentially explosive 

or 

fl

 ammable atmosphere. Failure to do so could 

result in 

fi

 re.

Do not insert your 

fi

 ngers or other 

objects into the air conditioner indoor or 

outdoor unit, rotating parts may cause 

injury.
Do not touch the outdoor unit during lightning, it 

may cause electric shock.
Do not expose yourself directly to cold air for a 

long period to avoid excess cooling.
Do not sit or step on the unit, you may 

fall down accidentally.

Remote control

Do not allow infants and small children to play 

with the remote control to prevent them from 

accidentally swallowing the batteries.

Power supply

Do not use a modi

fi

 ed cord, 

joint cord, extension cord or 

unspeci

fi

 ed cord to prevent 

overheating and 

fi

 re.

  

To prevent overheating, 

fi

 re or electric shock:

• Do not share the same power outlet with other 

equipment.

• Do not operate with wet hands. 

• Do not over bend the power supply cord.

• Do not operate or stop the unit by inserting or 

pulling out the power plug.

Indoor unit

Outdoor unit

Power supply

Remote control

Air inlet

Air inlet

Air inlet

Air inlet

Air outlet

Air outlet

Air outlet

Air outlet

Summary of Contents for CS-C12PKF-3

Page 1: ...hank you for purchasing Panasonic Air Conditioner Installation instructions attached Before operating the unit read these operating instructions thoroughly and keep them for future reference Model No Indoor Unit Outdoor Unit CS C12PKF 3 CS C18PKF 3 CS C24PKF 3 CU C12PKF 3 CU C18PKF 3 CU C24PKF 3 ...

Page 2: ...mum energy consumption Furthermore the sunlight sensor detects the sunlight intensity and helps control cooling temperatures to provide optimum comfort See To learn more for details nanoe G Deactivates harmful micro organisms such as viruses bacteria etc to keep air clean It also deactivates viruses and bacteria on the filter to keep inside of the unit clean Automatic Voltage Switcher AVS Monitors...

Page 3: ...RY AUTO COOL 2 Start stop the operation POWER AVS Please note that the OFF indication is on to start 3 Select the desired temperature Selection range 16 C 30 C Operating the unit within the recommended temperature may save energy COOL 26 C 28 C DRY 1 C 2 C lower than room temperature To dim or restore the unit s indicator brightness press and hold for 5 seconds Use remote control within 8 m from t...

Page 4: ...ric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc Do not install the unit in a potentially explosive or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner indoor or outdoor ...

Page 5: ...rong lightning activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for preservation of precise equipment food animals plants artwork or other objects This may cause quality deterioration etc Do not use any combustible equipment in front of the airflow outlet to avoid fire propaga...

Page 6: ...the operation mode Remote control display Indicator POWER AVS TIMER ECONAVI AUTO COMFORT NANOE G POWERFUL QUIET Orange Green Orange Green Green Blue Orange Green ECONAVI To optimise energy saving ECONAVI MODE To select operation mode AUTO For your convenience Unit selects the operation mode according to the room temperature Once AUTO mode is selected the unit will operate at the standard setting t...

Page 7: ...nce set For clock setting please refer to Quick guide See To learn more for details How to use AUTO COMFORT To maximise comfort AUTO COMFORT NANOE G To purify the air NANOE G nanoe G starts automatically when the unit is turned on with OFF ON Can be activated even when the unit is turned off In this condition the unit will operate as a fan with AUTO fan speed and louver swing To deactivate viruses...

Page 8: ... High activity Absent Set Fan Speed AUTO COMFORT Detecting human presence and activity the unit controls room temperature to keep human comfortable consistently e COOL DRY COOL DRY 1 C 2 C 1 C 1 tap 2 C 1 C During low activity fan speed 1 tap up for first 15 minutes or until set temperature is reached During human absence maximum fan speed for COOL DRY mode is medium fan nanoe G in filter deactiva...

Page 9: ...ir conditioner under the following temperature range DBT Dry bulb temperature WBT Wet bulb temperature Temperature C Indoor Outdoor DBT WBT DBT WBT COOL Max 32 23 55 31 Min 16 11 16 11 The human activity sensor will also scan for area of heat source and movement in a room Detection area Human activity indicator 120º 7m At left area At center multiple area At right area The unit judges human activi...

Page 10: ... TIMER ECONAVI AUTO COMFORT NANOE G POWERFU L QUIET Insert at both sides 1 Press both ends of the front panel 3 Close down 2 nanoe G Generator Every 6 months Clean with dry cotton bud Do not touch during operation Air filters Every 2 weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under shade away from fire or direct sunlight Replace ...

Page 11: ...m Check Operation in COOL mode is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet vents Noisy during operation Check if the unit has been installed at an incline Close the front panel properly Remote control does not work Display is dim or transmission signal is weak Insert the batt...

Page 12: ...al in other Countries outside the European Union These symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the requirement set by...