c. Indoor Fan Control
• During any operation mode combines with Patrol operation, fan speed follows respective operation mode.
• During Patrol individual operation if e-ion starts, only Auto Fan Speed and no Powerful operation is allowed. Even if “Fan
Speed” button is pressed, no signal is sent to air conditioner, and no change on LCD display.
• During Patrol individual operation if e-ion stops, Indoor Fan stop operation.
d. Airflow direction (Horizontal, Vertical) Control
• During any operation mode combines with Patrol operation, air flow direction follows respective operation mode.
• During Patrol individual operation if e-ion starts, only Auto Air Swing is allowed. Even if “Air Swing” button is pressed, no
signal is sent to air conditioner, and no change on LCD display.
• During Patrol individual operation if e-ion stops, Airflow direction louver closed.
e. Indicator
• When Patrol operation starts, Patrol Sensor indicator ON.
• When e-ion operation starts based on dirtiness level, e-ion indicator ON.
f. Remote Control Receiving Sound
g. Timer Control
• When ON timer activates when unit stops, previous operation resumes without Patrol operation.
• When ON timer activates during any operation, no change and carry on current operation.
• When OFF timer activates during any operation, all operation stops.
h. Power failure
• During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation resumes
immediately.
• During combination operation, if power failure occurs, after power resumes combination operation resume immediately.
•
Normal Operation
→
Patrol Mode
: Beep
•
Patrol Mode
→
Stop
: Long Beep
•
Patrol Mode
→
Normal Operation
: Beep
•
Stop
→
Patrol
: Beep
Summary of Contents for CS-C12GKF
Page 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control 5 1 1 CS C12GK ...
Page 10: ...10 5 2 Outdoor Unit 5 2 1 CU C12GK ...
Page 11: ...11 6 Refrigeration Cycle Diagram ...
Page 12: ...12 7 Block Diagram ...
Page 14: ...14 9 Electronic Circuit Diagram ...
Page 15: ...15 10 Printed Circuit Board 10 1 Indoor Unit TOP VIEW ...
Page 16: ...16 BOTTOM VIEW ...
Page 17: ...17 10 2 Indicator TOP VIEW BOTTOM VIEW ...
Page 46: ...46 ...
Page 47: ...47 15 2 Indoor Fan Motor and Cross Flow Fan Removal Procedures ...
Page 48: ...48 ...
Page 49: ...49 16 Technical Data 16 1 Thermostat Characteristics Cooling Soft Dry ...
Page 50: ...50 16 2 Operation Characteristics 16 2 1 CS C12GK CU C12GK ...
Page 51: ...51 ...
Page 53: ...53 ...