English
12
3. When including HR box
〈〈〈〈
PRECAUTIONS
〉〉〉〉
1.
A single switch can be used to supply power to units on the same system.
(However, branch switches, branch circuit breakers must be selected carefully.)
2.
Do not ground the equipment on gas pipes, water pipes or lightning rods, or crossground with telephones.
Improper grounding could result in electric shock.
9. FIELD SETTING
〈〈〈〈
Field setting must be made from the remote controller in accordance with the installation condition.
〉〉〉〉
•
Setting can be made by changing the “Mode number”, “FIRST CODE NO.”, and “SECOND CODE NO.”.
•
For setting and operation, refer to the “FIELD SETTING” in the installation manual of the remote controller.
9-1 Setting air filter sign
•
Remote controllers are equiped with liquid crystal display air filer signs to display the time to clean air filters.
•
Change the SECOND CODE NO. according to Table 3 depending on the amount of dirt or dust in the room.
(SECOND CODE NO. is factory set to “01” for filter contamination-light)
Table 3
9-2 Setting air flowrate increase mode
•
It is possible to raise set air flow (HIGH and LOW) from the field. Change the SECOND CODE NO. as
shown in Table 4 to suit your needs.
Table 4
Setting
Spacing time of display air filter
sign
Mode No.
FIRST CODE NO.
SECOND CODE NO.
Air filter
contamination-light
Approx. 200 hrs.
10 (20)
0
01
Air filter
contamination-heavy
Approx. 100 hrs.
02
Setting
Mode No.
FIRST CODE NO.
SECOND CODE NO.
Standard
13 (23)
0
01
A little increase
02
Increase
03
IN/D OUT/D
F
1
F
2
F
1
F
2
IN/D
OUT/D
F
1
F
2
F
1
F
2
P
1
P
2
L N
P
1
P
2
F
1
F
2
T
1
T
2
L N
Outdoor unit
HR box
No. 3
System
Control box
Control box
Indoor unit A
Power supply
220-240V
50Hz
or
220V
60Hz