Check Every 140 Hours (Once a Week)
1-4-6
Lubricating the X-Y Unit and Z Unit
NOTICE
This maintenance is current-carrying operation. When you open the safety cover,
the power of XY motor is cut. So be sure to open the safety cover to operate.
Lubricate the linear bearing and ball screw of the X-Y unit and Z unit.
∗
For DU/DHU specifications, it is necessary to remove the feeder base cover for the maintenance.
1-2-3 Setting and Removing the Feeder Base Cover (Only for DU/DHU Specifications)
Procedure for CM201-D/DU, CM202-D/DU
1.
Select the operation table.
2.
Press
UNLOCK
+ Grease up posi .
•
Each axis moves to the grease application
position.
3.
Ensure that there is nothing put under
the head and press Yes .
•
The Z axis moves down to the grease applica-
tion position.
4.
Turn OFF the servo switch.
5.
Open the safety cover.
To the next page
444C-E-MMA01-A07-08
444C-418E
Tools
Cloth and grease gun
Required time
15 minutes
Transfer head
2
1
OFF ( ) ON ( )
SERVO
444C-EEn-MpMmMm-011