34
5.5.
Jig’s Flow Diagram
Button Operation
Mecha
mode
LD
INNER
OUTER
LD_Open [Normal
Operation]
LD motor turns CW and
Open position
LO
L
H
stop when LOAD-SW = Signal change from LC-->LO
LD_Close [Normal
Operation]
LD motor turns CCW and
Close Position
LC
L
H
stop when LOAD-SW = Signal change from LO-->LC
Trv FW
[Normal Operation]
TRV motor turns CCW and
OPU Inner
LC
L
H
stops when INNER-SW = Signal change from H-->L
position
Trv REV
[Normal Operation]
TRV motor turns CW and
OPU Outer
LC
H
L
stops when OUTER-SW = Signal change from H-->L
position
LD-FW
[Manual mode]
LD motor turns CW and
Manual mode
~
~
~
stops when user release button
Trv motor FW
LD-REV
[Manual mode]
LD motor turns CCW and
Manual mode
~
~
~
stops when user release button
Trv motor Rev
Combi
[Aging Mode-1]
Mechanism in continuous cycle mode of combination between
Mode-1
~
~
~
Loading and Traverse function.
Load
[Aging Mode-2]
Mechanism in continuous cycle mode of Loading function.
Mode-2
~
~
~
Trv
[Aging Mode-3]
Mechanism in continuous cycle mode of Traverse function.
Mode-3
~
~
~
Switch state