5
BL-PA100A/BL-PA100KTA
2.2.
For Service Technician
ICs and LSIs are vulnerable to static electricity.
When replacing, the following precautions will help to prevent recurring malfunctions.
1. Cover the plastic parts with aluminum foil.
2. Use a conductive mat on the work-table.
3. Do not grasp IC or LSI pins with bare fingers.
2.3.
INSULATION RESISTANCE TEST
1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
2. Measure the resistance value with ohmmeter between the jumpered AC plug and Exposed Metal (LAN Connector).
Note:
Some exposed parts may be isolated from the chassis by design. These will read infinity.
3. If the measurement is outside the specified limits, there is a possibility of shock hazard. The equipment should be repaired
and rechecked before it is returned to the customer.
2.4.
CAUTION
The power socket wall outlet should be located near this equipment and be easily accessible.
2.5.
Trademarks
• Linux® is the registered trademark of Linus Torvalds in the U.S. and other countries.
• All other trademarks identified herein are the property of their respective owners.
Summary of Contents for BL-PA100A - HD-PLC Ethernet Adaptor
Page 15: ...15 BL PA100A BL PA100KTA 8 1 3 3 Function Check Flow Chart ...
Page 16: ...16 BL PA100A BL PA100KTA 8 2 Trouble Shooting Guide 8 2 1 Starting Up Operation Flow Chart ...
Page 18: ...18 BL PA100A BL PA100KTA ...
Page 26: ...26 BL PA100A BL PA100KTA 9 2 3 Cautions for Cord Label Attach power cord to label ...
Page 27: ...27 BL PA100A BL PA100KTA 9 2 4 Cautions for Main Board Assembly ...
Page 28: ...28 BL PA100A BL PA100KTA 9 2 5 Cautions for Affixing Master Label ...
Page 34: ...34 BL PA100A BL PA100KTA 10 5V PC802 5ms div 5ms div 5ms div 10 5V 3 3V ...
Page 38: ...38 BL PA100A BL PA100KTA 14 2 Accessories and Packing Materials BL PA100A ...
Page 39: ...39 BL PA100A BL PA100KTA 14 3 Accessories and Packing Materials BL PA100KTA ...