background image

© 2006 Panasonic Communications Co., Ltd. All
rights reserved. Unauthorized copying and distribu-
tion is a violation of law.

Order No. KMS0603209CE

F15

HD-PLC Ethernet Adaptor

BL-PA100A
BL-PA100KTA

(for U.S.A.) 

Summary of Contents for BL-PA100A - HD-PLC Ethernet Adaptor

Page 1: ... 2006 Panasonic Communications Co Ltd All rights reserved Unauthorized copying and distribu tion is a violation of law Order No KMS0603209CE F15 HD PLC Ethernet Adaptor BL PA100A BL PA100KTA for U S A ...

Page 2: ...C Address Label 21 9 Disassembly and Assembly Instructions 22 9 1 Disassembly Instructions 22 9 2 Assembly Instructions 24 10 Block Diagram 29 10 1 BL PA100A BL PA100KTA BLOCK DIAGRAM 29 10 2 POWER SUPPLY BLOCK DIAGRAM 30 11 Schematic Diagram 31 11 1 For The Schematic Diagram 31 11 2 Schematic Diagram 32 11 3 Waveform 33 12 Printed Circuit Board 35 12 1 Power Supply Board Component View 35 12 2 Po...

Page 3: ...ndard Pb solder can also be used Caution PbF solder has a melting point that is 50 70 F 30 40 C higher than Pb solder Please use a soldering iron with tempera ture control and adjust it to 700 20 F 370 10 C In case of using high temperature soldering iron please be careful not to heat too long PbF solder will tend to splash if it is heated much higher than its melting point approximately 1100 F 60...

Page 4: ...4 BL PA100A BL PA100KTA 2 1 2 How to Recognize That Pb Free Solder is Used MAIN BOARD POWER SUPPLY BOARD ...

Page 5: ... resistance value with ohmmeter between the jumpered AC plug and Exposed Metal LAN Connector Note Some exposed parts may be isolated from the chassis by design These will read infinity 3 If the measurement is outside the specified limits there is a possibility of shock hazard The equipment should be repaired and rechecked before it is returned to the customer 2 4 CAUTION The power socket wall outl...

Page 6: ...on speed 1 UDP Max 70 Mbps TCP 2 Max 42 Mbps Maximum recommended no of adaptors per network 3 16 including the master Maximum recommended no of network devices connected to an adaptor 4 8 Standard IEEE 802 3 IEEE 802 3u Interface 10 Base T 100 Base TX Auto MDI MDI X Protocol IPv4 IPv6 TCP UDP Access method CSMA CD Indicators PLC blue red LAN green orange MASTER green Other Mode Selector MASTER or ...

Page 7: ... your HD PLC adaptors into your existing home network Easy to expand Up to 16 adaptors in all can be used which means you can add additional adaptors whenever you need to add a network con nection in another room of the house Simple network speed testing You can confirm the speed of each adaptor s HD PLC connection by simply pressing a button Fast reliable and secure With speeds of up to 190 Mbps ...

Page 8: ...rom the secondary side The output voltage is feed back in the IC801 according to the error detect circuit When Vin increase IC801 s on duty Ratio decrease As a result Charge of energy to the switching transformer primary coil becomes the same as Low Vin and Vout is kept constant When Iout increase IC801 s on duty Ratio increase As a result Charge of energy to the switching transformer primary coil...

Page 9: ...put increases because the error detecting circuit is broken The internal circuit of IC801 will recognize this sig nal and output becomes 0V Thermal Shutdown Circuit IC801 become shutdown when internal temperature becomes 130 degrees C typ PLC Coupling Circuit This circuit superimposes a PLC signal on AC voltage from a MAIN board Async Circuit This circuit outputs the rectangle waveform which synch...

Page 10: ... Used to register the adaptor or test the terminal is network speed 5 Mode Selector The position of this selector during registration determines whether the adaptor is used as the master or as a terminal 6 AC IN Connects the adaptor to AC power as well as to the HD PLC network 7 FACTORY DEFAULT RESET Button Used to reset the adaptor and erase its registration 8 LAN Jack Connects the adaptor to a n...

Page 11: ...tor to your broadband internet router or modem and then connect the other adap tors to your network devices computers network printers network cameras etc When you re finished each network device will be able to access the internet as well as each other Master and terminal adaptors Before using your adaptors it is important to understand the concept of a master adaptor and a terminal adaptor An HD...

Page 12: ...ult 3 Refer to the chart below to determine the network speed 4 If you are not satisfied with the speed test result connect the terminal to a different wall outlet and repeat the test Note At least one indicator Good network speed must be lit in order to use the terminal If you are not satisfied with the speed test result and have tried connecting the terminal to different wall outlets refer to th...

Page 13: ...13 BL PA100A BL PA100KTA 8 Troubleshooting Guide 8 1 Basic Check 8 1 1 Connection 8 1 2 Check LED Ether ...

Page 14: ...ct Adaptors and Initializes 1 Set Standard PLC Mode Selector Switch is set to MASTER 2 Set Test PLC Mode Selector Switch is set to TERMINAL 3 LAN Jack Connect both LAN Jack with an ethernet cable 4 Power ON Plug the Power cord in the same side of the Power Strip 5 Reset both PLC to factory default Push each FACTRY DEFAULT RESET Button of Standard PLC and the Test PLC for about two seconds ...

Page 15: ...15 BL PA100A BL PA100KTA 8 1 3 3 Function Check Flow Chart ...

Page 16: ...16 BL PA100A BL PA100KTA 8 2 Trouble Shooting Guide 8 2 1 Starting Up Operation Flow Chart ...

Page 17: ...age test withstanding voltage test intentional short circuit test etc Caution If you find a opened fuse in the unit do not turn on the power until you locate and repair the faulty parts except for the fuse otherwise the fuse will open again and you cannot pinpoint the faulty point In most cases the symptom is that nothing is output It is more likely that the fault is in the primary side rather tha...

Page 18: ...18 BL PA100A BL PA100KTA ...

Page 19: ... 1 Configuring TCP IP on your PC 1 Click Start Control Panel Network and Internet Connections and then click Network Connections 2 Right click your LAN connection and then click Properties 3 Click Internet Protocol TCP IP and then click Properties ...

Page 20: ...er combination 5 Click OK and then click Close NOTE If your Brower IE uses Proxy we recommend to disable it 8 3 2 How to check the firmware of HD PLC adaptor 1 Open the following web page by using IE http 192 168 20 156 nca32 update cgi Note If this page is not displayed execute arp d by Dos prompt ...

Page 21: ...n When you replace the main board you must also attach the new MAC address label included with the main board Attach the new MAC address label to the unit by placing over the old MAC address label Make sure the old address cannot be seen Throw away the old main board It cannot be reused ...

Page 22: ...over the old MAC address label Make sure the old address cannot be seen Throw away the old main board It cannot be reused IF the MAC address of the old main board is already registered via DDNS and then used in a different camera the camera can not be used with DDNS service 1 Remove the Grill 2 Remove the 2 screws A 3 Remove the Cabinet Cover 4 Remove the 2 screws A 5 Remove the Cover 6 Remove the...

Page 23: ...23 BL PA100A BL PA100KTA 10 Remove the 2 screws A 11 Remove the Cover 12 Remove the Power Supply Board ...

Page 24: ...24 BL PA100A BL PA100KTA 9 2 Assembly Instructions 9 2 1 Cautions for Heat Sink 1 Attach four Hear Sink A and Heat Sink B to Cover ...

Page 25: ...25 BL PA100A BL PA100KTA 9 2 2 Cautions for Button and Knob Button Caution Push Button completely Knob Caution Attach Knob to right head edge ...

Page 26: ...26 BL PA100A BL PA100KTA 9 2 3 Cautions for Cord Label Attach power cord to label ...

Page 27: ...27 BL PA100A BL PA100KTA 9 2 4 Cautions for Main Board Assembly ...

Page 28: ...28 BL PA100A BL PA100KTA 9 2 5 Cautions for Affixing Master Label ...

Page 29: ...net PLC LSI SDRAM 128Mbit Ether PHY D A PLC TX Front End PLC RX Front End A D D D Converter Power P C B See POWER SUPPLY BLOCK DIAGRAM Main P C B SW LED Control I F PLC Front End PLC L N Async 10 5V BL PA100A BL PA100KTA BLOCK DIAGRAM 3 3V 1 2V 10 5V F ROM 8Mbit TCXO 31 25MHz D D Converter ...

Page 30: ...rcuit AC Input Line Filter Circuit Rectifier Circuit Surge Absorber Circuit Converter Control Circuit PLC Coupler Capacitor Async Pulse Generator Circuit 10 5V Output Circuit Error Detect Circuit Vout SG GND Async PLC L N Async Output Circuit Photo Coupler Photo Coupler Vin 10 5V Iout PLC Coupling Circuit Async Circuit POWER SUPPLY BLOCK DIAGRAM ...

Page 31: ...c Diagram 11 1 For The Schematic Diagram Note 1 DC voltage measurements are taken with an oscilloscope or a tester with a ground 2 The schematic diagrams and circuit board may be modified at any time with the development of new technology ...

Page 32: ... 7 SOURCE 7 8 SOURCE 8 TP802 10 5V TP803 GND TP801 VD D802 600V 1A R810 100k 0 25W R811 100k 0 25W R812 18k D806 MA2S72800L R806 4 3k R802 1 5M 0 25W R803 1 5M 0 25W C803 4700p 250V R825 0 R826 0 TP804 PLC L TP805 PLC N B1ADCF000011 Q802 E C B PC802 B3PBA0000441 1 2 3 4 C820 1000p C809 1u D809 200V 1A C0DAEYY00006 IC802 1 Vref 2 A 3 K D808 5 6V 150mW MAZS0560ML D805 NC D807 MAZS0430H L R828 47k 0 ...

Page 33: ...33 BL PA100A BL PA100KTA 11 3 Waveform ZNR801 IC801 4 D801 Q801 D802 Q802 C IC801 5 T802 7 5ms div 5ms div 5ms div 5ms div 5ms div 5ms div 5ms div 5ms div 170V 170V 280V 170V 15V 4 8V 14 5V 170V 11V 17V ...

Page 34: ...34 BL PA100A BL PA100KTA 10 5V PC802 5ms div 5ms div 5ms div 10 5V 3 3V ...

Page 35: ...802 IC801 L802 J801 J803 J805 J806 ZNR801 1 4 4 3 2 L N F801 PQUP11364Z PbF BL PA100A POWER SUPPLY BOARD Component View R804 R810 R811 R834 R818 R817 R814 R812 R803 R801 R802 D807 D804 D810 D809 D805 D806 R806 R808 R832 R807 R821 R820 R829 R822 R823 R805 R830 R819 R833 R809 C812 C809 C808 C819 L804 C818 C822 C821 C820 C811 ACIN ACIN ACIN ACIN R816 Q802 C814 C802 C803 R839 R838 R828 D803 D802 D808 ...

Page 36: ...36 BL PA100A BL PA100KTA 13 Appendix Information of Schematic Diagram 13 1 Terminal Guide of ICS Transistors and Diodes ...

Page 37: ...ach the new MAC address label included with the main board Attach the new MAC address label to the unit by placing over the old MAC address label Make sure the old address cannot be seen Throw away the old main board It cannot be reused IF the MAC address of the old main board is already registered via DDNS and then used in a different camera the camera can not be used with DDNS service ...

Page 38: ...38 BL PA100A BL PA100KTA 14 2 Accessories and Packing Materials BL PA100A ...

Page 39: ...39 BL PA100A BL PA100KTA 14 3 Accessories and Packing Materials BL PA100KTA ...

Page 40: ...C HB 6 PQBC10457Z1 BUTTON ABS V0 7 PQBD10041Z1 KNOB ABS V0 8 PQMY10035Z HEAT SINK A 9 PQMY10036Z HEAT SINK B 10 PQMH10488Z COVER 11 PQKF10697Z1 CABINET COVER ABS V0 12 PQKV10053Z1 COVER ABS V0 13 PQQS11231Z LABEL MASTER BL PA100KTA ONLY A XTW2 R6PFJ SCREW Safety Ref No Part No Part Name Description Remarks A1 PSJA1069Z POWER CORD A2 PQQS11256Z LABEL A3 PQQX15015Y INSTRUCTION BOOK A4 PQQW15388Z LEA...

Page 41: ...LER PC802 B3PBA0000441 PHOTO COUPLER R801 PQ4R18XJ155 1 5M S R802 PQ4R18XJ155 1 5M S R803 PQ4R18XJ155 1 5M S R804 PQ4R18XJ473 47k S R807 ERJ6ENF5602 56k R808 ERJ3EKF4702 56k R809 ERJ3GEYJ202 2k R810 PQ4R18XJ104 100k S R811 PQ4R18XJ104 100k S R812 ERJ3GEYJ183 18k R813 ERJ3GEYJ473 47k R814 ERJ3GEYJ154 150k R815 ERJ3GEYJ683 68k R816 ERJ3GEYJ104 100k R817 ERJ3GEYJ225 2 2M R818 ERJ3GEYJ392 3 9k R819 PQ...

Reviews: