background image

- 5 (E) -

Major operating controls and their functions

SDI card

 EVF I/F connector [EVF I/F]

The EVF I/F cable 

9

 from the interface 

bracket is connected here.

  SDI output 1, 2 connector  

[SDI OUT 1, 2]

SDI signals are output from here.

 Setting switches

SW NO

OFF

ON

1

EDH

ENABLE DISABLE

 SETTING

E50

E860

 DATA CLIP NORMAL

CLIP

4 NTSC/PAL

NTSC

PAL

1:  EDH <ENABLE/DISABLE>

 

(Factory setting: ENABLE) 
An EDH flag is added to SDI output at 
the ENABLE setting.

2:  Model selection <E350/E860>

 

(Factory setting: E50) 
When the AW-E50, AW-E650,  
AW-E655 or AW-E750 is used, set 
this switch at the E50.  
When the AW-E860 is used, set this 
switch at the E860. 

3:  DATA CLIP <NORMAL/CLIP>

 

(Factory setting: NORMAL) 
At the NORMAL setting, signal input 
is output at the same level at which it 
was input. 
At the CLIP setting, signal input at 
less than 0% is output at 0%, and 
signal input at more than 100% is 
clipped at 100%.

4:  NTSC/PAL switching <NTSC/PAL>

 

(Factory setting: NTSC) 
Leave this switch at the factory setting.

Summary of Contents for AW-PB506AL

Page 1: ...ISH ITALIANO ESPAÑOL 中 文 РУССКИЙ Before attempting to connect operate or adjust this product please read these instructions completely Studio SDI Card AW PB506AL This product consists of an SDI card and an interface bracket ...

Page 2: ...ING LIQUIDS AND DO NOT PLACE ANY LIQUID CONTAINERS ON TOP OF THE EQUIPMENT CAUTION TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNOYING INTERFERENCE USE THE RECOMMENDED ACCESSORIES ONLY CAUTION TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD REFER CHANGES OF SWITCH SETTINGS INSIDE THE UNIT TO QUALIFIED SERVICE PERSONNEL DO NOT REMOVE PANEL COVERS BY UNSCREWING To reduce the risk of electric shock do...

Page 3: ...ctly will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business...

Page 4: ... camera 8 Mounting the viewfinder on a bracket 8 Connections 9 When configuring a system with the remote control unit 9 When configuring a system with the remote operation panel 10 Setting and changing of menu items 11 Performing the settings 11 Optional card settings submenu 13 Appearance 14 SDI card 14 Interface bracket 15 Specifications 16 Accessories Adjuster plug M6 M3 1 Screws 6 mm 2 Screws ...

Page 5: ...ra such as the AW E350 AW E650 AW E655 AW E750 and AW E860 and mounting the camera on the interface bracket makes it possible for a viewfinder and or inter communications headset to be used and thus enable the camera to be used as a studio camera In addition there are two signal outputs for SDI signals compliant with EBU Tech 3267 E standard Notes The AW PB506A cannot be installed to the following...

Page 6: ... An EDH flag is added to SDI output at the ENABLE setting 2 Model selection E350 E860 Factory setting E350 When the AW E350 AW E650 AW E655 or AW E750 is used set this switch at the E350 When the AW E860 is used set this switch at the E860 3 DATA CLIP NORMAL CLIP Factory setting NORMAL At the NORMAL setting signal input is output at the same level at which it was input At the CLIP setting signal i...

Page 7: ...64 does not come with a standby function 7 Inter communications level control LEVEL This adjusts the sound level output to the inter communications headset 8 Inter communications jack M3 INCOM The inter communications headset is connected here If the plug diameter does not match use the adjuster plug M6 M3 supplied with this product MIC Dynamic With Preamp 50 20 dB Receiver 150 max 200 mW 9EVF I F...

Page 8: ...over 4 Align the SDI card with the guides and insert it Ensure the card is fully inserted 5 Firmly tighten the 2 screws 6 mm to the optional card slot 6 Firmly secure the rear panel with the 4 screws 8 mm Note If the screws are misplaced use the extra screws supplied with this product Before installing the SDI card Release the static carried in the body of the person to perform the installation In...

Page 9: ...supplied to the viewfinder onto the top of the interface bracket using the 2 screws provided Mount the base securely so that it is not unsteady 4 Slide the viewfinder onto the mounting base and tighten the fixing knob to secure it firmly 5 Connect the viewfinder cable to the EVF connector 1 or 2 on the interface bracket 6 Connect the EVF I F cable from the interface bracket to the EVF I F connecto...

Page 10: ...le camera Power to the camera is supplied from the remote control unit Viewfinder WV VF65B AW VF80 AW VF64 etc Inter communications headset Convertible camera AW E350 AW E650 AW E655 AW E750 AW E860 etc SDI monitor Video monitor SDI output Coaxial cable BBC No PSF1 2M BELDEN 8281 or equivalent coaxial cable max 200 m Remote control unit RCU WV RC700A WV RC550 AW RC600 etc Composite signals Coaxial...

Page 11: ... Inter communication between the remote operation panel and studio SDI card is not possible When configuring a system with the remote operation panel Viewfinder WV VF65B AW VF80 AW VF64 etc Convertible camera AW E350 AW E650 AW E655 AW E750 AW E860 etc SDI monitor Video monitor SDI output Remote operation panel AW CB400 etc Control cable AW CA50T8G TALLY cable AC adapter AW PS505A AC adapter AW PS...

Page 12: ...his is displayed when the convertible camera is used to perform the settings Option Card 2 is displayed on the menu when the optional card has been plugged into the optional card slot of the additional card box MENU switch ITEM AWC switch YES ABC switch NO BAR switch MENU switch DATA YES UP switch ITEM UP switch ITEM DOWN switch DATA NO DOWN switch Camera settings to match the system configuration...

Page 13: ...ENU or ITEM AWC switch to move the flashing to the desired setting item then press the YES ABC or NO BAR switch to change the setting When performing the settings with the remote control unit AW RC600 Press the ITEM UP or ITEM DOWN switch to move the flashing to the desired setting item then press the DATA YES UP or DATA NO DOWN switch to change the setting 4 Return to filming mode When performing...

Page 14: ...le when ON has been selected for the Zebra indicator 1 setting 3Safety zone 1 to 4 OFF This selects the type of safety zone that is displayed in the viewfinder If OFF is selected a safety zone will not be displayed Note The safety zone and the center marker reflect the electrical positions which may differ from the optical positions The inner frame and the outer frame are approximately 90 and 95 r...

Page 15: ... 14 E ENGLISH 92 21 5 70 Appearance Unit mm SDI card 111 ...

Page 16: ... 15 E 183 190 Appearance Unit mm Interface bracket 141 30 50 ...

Page 17: ...r 2 6 pin round composite signals brightness 1 0 V P P Inter communications jack M3 TALLY input connector BNC Switch control functions SDI card EDH ENABLE DISABLE Model selection E350 E860 DATA CLIP NORMAL CLIP NTSC PAL switching NTSC PAL Interface bracket EVF standby VIDEO ON OFF switch WV VF65B AW VF80 ST BY ON AW VF64 VIDEO ON VIDEO OFF Inter communications level control Menu screens Zebra indi...