![Panasonic AW-HN130WPC Operating Instructions Manual Download Page 112](http://html1.mh-extra.com/html/panasonic/aw-hn130wpc/aw-hn130wpc_operating-instructions-manual_3670186112.webp)
Troubleshooting
Operation
Symptom
Cause and solution
Reference pages
No power
• Is the AC adaptor securely connected to the AC outlet?
– – –
• If the power plug of the AC adaptor connected properly?
– – –
• Is the LAN cable connected securely to the IP control LAN connector
<LINK/ACT>?
page 18
•
Is the network cable for the PoE+ (IEEE802.at) compatible power supply device
and the unit connected properly?
Installation Instructions
• Power may not be supplied if the total power limit is exceeded on power supply
devices that allow connections to multiple PoE+ terminals.
→ Refer to the operating instructions for the PoE+ power supply device.
– – –
• If the unit is connected to the controller, has it been connected properly?
→ Refer to the operating instructions for the controller.
Installation Instructions
• When performing operations from a wireless remote control
→ Also refer to the “Cannot operate using the wireless remote control” item.
– – –
Cannot operate
( common to wireless remote control,
controller)
• Is the power on?
→ If the unit’s status display lamp is off or lights up orange, it means that the unit’s
power is not on.
page 25
• The safe mode function may have been activated.
page 111
• Have the limiter functions been set?
pages 109 to 110
• Has the unit you want to operate been selected properly?
page 26
Cannot operate using the wireless
remote control
• Have the remote control’s batteries run down or have the batteries been installed
with their polarities reversed?
→ If the status display lamp does not blink even when the wireless remote control is
operated near the wireless remote control signal light-sensing area, it means that
the batteries have run down. Replace the batteries.
– – –
• Have the IR ID switches been set correctly?
page 18, page 22
• Is there a fluorescent light or plasma monitor near the unit and, if so, is the
wireless remote control signal light‑sensing area exposed to its light?
page 16
Cannot operate using the controller
• Is the unit connected to the controller properly?
→ Refer to the operating instructions for the controller.
Installation Instructions
• The user authorization and host authorization must be set to OFF when the AW‑
RP120, AW‑RP50 and AK‑HRP200 remote camera controllers are connected in a
network.
page 87, page 88
• It may be necessary to upgrade the version of the controller so that the controller
will support the unit.
→ For details on upgrading, visit the support page on the following website.
http://pro-av.panasonic.net/
– – –
• When using an HTTPS connection, network connection with the AW‑RP50, AW‑
RP120, and AK‑HRP200 will be disabled.
page 93, page 98
The unit turns in the opposite
direction to the one operated
• Has the stand‑alone (Desktop) installation setting been selected correctly?
page 56, page 84
• The reversal setting may have been established at the controller if the unit is
connected to the controller.
→ Refer to the operating instructions for the controller.
– – –
112