Technical Terminology & Cautions for Use (Detection Switches)

TECHNICAL TERMINOLOGY

Detection Switches

A compact switch equipped with an enclosed micro-gap snapaction 

contact mechanism that makes a specified motion with a specified 

force to open/close a circuit, and an actuator outside the enclosure 
(hereinafter referred to as the switch)

Actuator

A part of the switch that transmits the received external force to an 
internal spring mechanism to move the movable contact so that the 
switch can be opened and closed

Actuator stopper

A part of the switch to limit the actuator movement in the switch 
operation direction

Rated values

Values indicating the characteristics and performance guarantee 
standards of the snap-action switches. The rated current and rated 

voltage, for instance, assume specific conditions (type of load, 
current, voltage, frequency, etc.).

Mechanical life

The service life when operated at a preset operating frequency 
without passing electricity through the contacts. (The life test is 
performed at a switching frequency of 60 times/minute and 
operating speed of 100 mm/second at the regular cam.)

Electrical life

The service life when the rated load is connected to the contact and 
switching operations are performed. (The life test is performed at a 

switching frequency of 20 times/minute and operating speed of 100 

mm/second at the regular cam.)

Contact form

This refers to the components determining the type of application 

which make up the electrical input/output circuits in the contact.

SPDT

SPST-N.C.

SPST-N.O.

Insulation resistance

Resistance between non-continuous terminals, each terminal and 
other exposed metal parts and between each terminal and ground.

Dielectric

Threshold limit value that a high voltage can be applied to a 
predetermined measuring location for one minute without causing 
damage to the insulation.

Contact resistance

This indicates the electrical resistance at the contact part.

Generally, this resistance includes the conductor resistance of the 

spring and terminal portions.

Vibration resistance

Malfunction vibration ... Vibration range where a closed contact does 

not open for longer than a specified time due to vibrations during 

use of the snap-action switches.

Shock resistance

Shock durability ... Shock range where the mechanical shocks 

received during snap-action switches transport and installation do 
not damage the parts or harm the operating characteristics.
Malfunction shock ... Shock range where a closed contact does not 

open for longer than a specified time due to shocks during use of 

the snap-action switches.

ー 8 ー

Summary of Contents for AV620264

Page 1: ...ying machine Printer Also for all types of equipment required for maintenance and inspections Unit mm 29 2 10 7 ORDERING INFORMATION PART NO AV 6 64 Operating Force OP by pin plunger Max 2 0 50 N 5 1 50 N Contact material 64 CuNi alloy Au clad contact Contact form 2 SPST NC Plunger color Red 3 SPST NO Plunger color Yellow Lever position Nil Standard 12 Backward Actuators 0 Pin plunger 2 Hinge leve...

Page 2: ... 60 cpm Electrical Rated load OT Max Min 2 105 at 20 cpm Insulation resistance Min 100 MΩ Dielectric strength Between non continuous terminals 1 000 Vrms for 1 min Between each terminal and other exposed metal parts 1 500 Vrms for 1 min Between each terminal and ground 1 500 Vrms for 1 min Contact resistance initial 100 mΩ max by voltage drop 0 1 A 6 to 8 V DC Value includes the resistance between...

Page 3: ...06 N Simulated roller lever 0 20 N 0 02 N 2 6 mm 0 8 mm 1 2 mm 12 2 0 8 mm 0 50 N 0 06 N Roller lever 0 20 N 0 02 N 2 6 mm 0 8 mm 1 2 mm 15 7 0 8 mm 0 50 N 0 06 N 2 Lever position Backward Actuator Operating Force OF Max Release Force RF Min Pretravel PT Max Movement Differential MD Max Overtravel OT Min Operating Position OP Hinge lever 0 35 N 0 03 N 1 4 mm 0 6 mm 0 7 mm 9 2 0 6 mm 1 00 N 0 10 N ...

Page 4: ...General tolerance 0 25 DIMENSIONS CAD The CAD data of the products with a CAD mark can be downloaded from our Website Unit mm CAD External dimensions Pin plunger Pretravel PT Max 0 6 mm Movement Differential MD Max 0 1 mm Overtravel OT Min 0 4 mm Operating Position OP Distance from mounting hole 8 4 0 3 mm CAD Lever position Standard External dimensions Hinge lever Pretravel PT Max 2 6 mm Movement...

Page 5: ...1 4 19 2 General tolerance 0 25 4 0 2 5 7 2 4 2 4 0 05 0 1 φ2 4 0 05 0 1 9 5 0 08 2 5 0 1 5 7 29 2 CAD Lever position Standard External dimensions Simulated roller lever Pretravel PT Max 2 6 mm Movement Differential MD Max 0 8 mm Overtravel OT Min 1 2 mm Operating Position OP Distance from mounting hole 12 2 0 8 mm Lever position Backward External dimensions Pretravel PT Max 1 4 mm Movement Differ...

Page 6: ...External dimensions Pretravel PT Max 1 4 mm Movement Differential MD Max 0 6 mm Overtravel OT Min 0 7 mm Operating Position OP Distance from mounting hole 14 9 0 6 mm 2 5 OP 15 7 0 8 PT Max 2 6 General tolerance 0 25 7 φ2 4 0 05 0 1 2 5 0 1 9 5 0 08 5 7 29 2 7 7 10 0 2 4 0 05 0 1 12 9 18 CAD Lever position Standard External dimensions Roller lever Pretravel PT Max 2 6 mm Movement Differential MD M...

Page 7: ...o not use any connector other than the specified connector or solder the terminals directly 2 Make sure leads are arranged so that no constant force is applied to them when the connectors are mated 3 Keep the connector straight when inserting it If it is inserted at an angle it may snag near the entrance or it may be inserted too forcefully 4 Problems thought to be caused by the XA connector which...

Page 8: ...Electrical life The service life when the rated load is connected to the contact and switching operations are performed The life test is performed at a switching frequency of 20 times minute and operating speed of 100 mm second at the regular cam Contact form This refers to the components determining the type of application which make up the electrical input output circuits in the contact SPDT SPS...

Page 9: ...equired to move from an operating position to a total travel position Movement Pretravel PT mm degree Max Distance or agree of the actuator movement from free position to operating position Overtravel OT mm degree Min The distance or degree which the actuator is permitted to travel after actuation without any damage to the switching mechanism Movement Differential MD mm degree Max The distance or ...

Page 10: ...in contact failures or contact fusion 2 An extremely high activation speed may cause damage to contacts or contact response failure Driving Mechanism Use of a driving mechanism which will cause physical impact to the actuator should be avoided Example Bad Good TECHNICAL NOTES ON ELECTRICAL CHARACTERISTICS 1 The snap action switch is designed for AC operations While it has small contact gaps and no...

Page 11: ... AC and DC Impedance of r is nearly equal to impedance of R C 0 1 μF R diode Contact for snap action switch 1 For DC circuits only ZNR Varistor Contact for snap action switch Induction load Can be used for both AC and DC 2 Do not connect the contacts on individual switches to different type or different poles of the power supply Examples of power supply connections connection to different poles PL...

Page 12: ...ing hole 2 Depressed position The plunger lever should be pressed down to 70 or more of OT Over Travel Therefore the depressed position should be calculated based on the minimum value of OP Operating Position and the 70 and 100 of the OT value OP Min 70 of OT 8 0 0 84 7 16 mm OP Min 100 of OT 8 0 1 2 6 80 mm The plunger lever should be pressed down to the position of 6 80 to 7 16 mm from the mount...

Page 13: ...sation can cause adverse conditions such as deterioration of insulation coil cutoff and rust Condensation or other moisture may freeze on the switch when the temperatures is lower than 0 C 32 F This causes problems such as sticking of movable parts or operational time lags The plastic becomes brittle if the switch is exposed to a low temperature low humidity environment for long periods of time St...

Page 14: ...r is required Hinge lever Large Medium Small Possible Little force required for operation Appropriate for use with low speed cams and dogs has large stroke Lever available in various shapes to fit operating unit Simulated roller lever Large Medium Small Possible Tip of hinge lever is bent into a semi circle enabling use as a simple roller type Leaf lever Large Large Small Excellent Play in lever i...

Page 15: ...Electromechanical Control Business Division industral panasonic com ac e Specifications are subject to change without notice 1006 Oaza Kadoma Kadoma shi Osaka 571 8506 Japan Panasonic Corporation 2021 AECTB60E 202110 ...

Reviews: