56
11.1.6 Installation Of Remote Controller
As Room Thermostat
Remote
Controller
3
mounted to the Indoor Unit
can be moved to the room and serve as Room
Thermostat.
11.1.6.1 Installation
Location
Install at the height of 1 to 1.5 m from the floor
(Location where average room temperature can
be detected).
Install vertically against the wall.
Avoid the following locations for installation.
1. By the window, etc. exposed to direct sunlight
or direct air.
2. In the shadow or backside of objects deviated
from the room airflow.
3. Location where condensation occurs (The
Remote Controller is not moisture proof or
drip proof.)
4. Location near heat source.
5. Uneven
surface.
Keep distance of 1 m or more from the TV, radio
and PC. (Cause of fuzzy image or noise)
11.1.6.2 Remote
Controller
Wiring
1
2
Terminal for Remote Controller wiring
Remote Controller
Indoor unit
Remote Controller wiring
(
fi
eld supply)
•
No polarity
Remote Controller cable shall be (2 × min 0.3
mm
2
), of double insulation PVC-sheathed or
rubber sheathed cable. Total cable length shall be
50 m or less.
Be careful not to connect cables to other terminals
of Indoor Unit (e.g. power source wiring terminal).
Malfunction may occur.
Do not bundle together with the power source
wiring or store in the same metal tube. Operation
error may occur.
11.1.6.3 Remove The Remote Controller
From Indoor Unit
1. Remove the top case from the bottom case.
Bottom
case
Flat-blade
screwdriver
Insert the
driver and
slightly turn.
2. Remove the wiring between Remote controller
and Indoor Unit terminal. Remove the bottom case
from the Control board cover by loosening the
screws. (3 pieces)
Disconnect the
Remote controller
wiring
Claw
(2 places)
11.1.6.4 Mounting The Remote
Controller
For exposed type
Preparation:
Make 2 holes for screws using a driver.
UP
Cut here with
a nipper and
remove the burr
with a
fi
le.
Mount the top case.
•
Align the claws of the top
case and then align the claws
of the bottom case.
Hole for screw
Screw
(
fi
eld supply)
Claw (2 places)
Pass through
the hole
Bottom case
(Back side)
Top case
(Back side)
Remote controller terminal board
Remove the coating. Approx. 6 mm
Remove the sheath. Approx. 180 mm.
Make sure the wiring connection is in the
correct direction.
Clamper
(
fi
eld supply)
Claw (2 places)
Wall to which
the remote
controller is
fi
xed
Mount the bottom case to
the wall.
Connect the remote control
wiring
•
Arrange the wires along the groove
of the case.
For embedded type
Preparation:
Make 2 holes for screws using a driver.