42
No.
Function
name
Changes
during RUN
Setting range
Unit
Initial
value
P034
Reverse
Run Lock
-
0: Forward/Reverse run enabled
1: Reverse run disabled
-
0
P035
Starting
Frequency
○
0.2 to 60.0
0.1[Hz]
0.2
P036
Stop Mode
-
0: Deceleration stop
1: Coast-to-stop
-
0
P037
Stop
Frequency
○
0.2 to 60.0
0.1[Hz]
0.2
P038 DC Braking
Time
○
0.0 to 120.0
0.1[sec]
0.0
P039 DC Braking
Level
○
0 to 100
1[%]
0
P040
Stop
Frequency
during
Forward /
Reverse
Run
○
0.2 to 60.0
0.1[Hz]
0.2
P041
DC Braking
Time durig
Forward /
Reverse
Run
○
0.0 to 120.0
0.1[sec]
0.0
P042
DC Braking
Level
during
Forward/
Reverse
Run
○
0 to 100
1[%]
0
P043
DC Braking
Time during
Startup
○
0.0 to 120.0
0.1[sec]
0.0
P044
DC Braking
Level
during
Startup
○
0 to 100
1[%]
0
P045
Lower
Frequency
Limit
○
0.2 to 400.0
0.1[Hz]
0.2
P046
Upper
Frequency
Limit
○
0.2 to 400.0
0.1[Hz] 400.0
P047
Zero Dead
Stop
Function
Selection
-
0.0 · 0.2 to 400.0
0.1[Hz]
0.2
P048
1st Skip
Frequency
○
0.0 · 0.2 to 400.0
0.1[Hz]
0.0
P049 2nd Skip
Frequency
○
0.0 · 0.2 to 400.0
0.1[Hz]
0.0
Summary of Contents for AMK3000P22