75
C22
ERR0
C23
ERR1
C24
ERR2
Error status
0
0
0
SERVO NOT LOCKED (priority level 1)
0
0
1
SERVO LOCKED (priority level 4)
0
1
0
HIGH ERROR (amber) (priority level 3)
0
1
1
HIGH ERROR (red) (priority level 2)
Error statuses
C12
TC SRC1
C13
TC SRC2
TC input status
0
0
External SLTC
0
1
External LTC
1
0
External SVITC (or external VITC with SD input)
1
1
INT
TC input statuses
C10
CAS INH1
C11
CAS INH2
Tape recording inhibit status
0
0
Cassette recording enabled
0
1
Cassette accidental erasure prevented
Tape recording inhibit statuses
Recording inhibit statuses
Function menus
<50P IN/OUT ASSIGN>
C08
REC INH1
C09
REC INH2
Recording inhibit statuses
0
0
Overwriting prohibited during normal recording
0
1
All recording onto cassette prohibited
1
0
Recording inhibit mode other than the 2 above modes
1
1
Recording onto cassette enabled
Down-conversion statuses
C14
DC1
C15
DC2
C16
DC3
Down-conversion status
0
0
0
Squeeze mode
0
1
0
Side cut modea
1
0
0
Letter box mode
1
1
0
14:9
1
1
1
13:9
Up-conversion statuses
C17
UC1
C18
UC2
Up-conversion status
0
0
Stretch mode
0
1
Side panel mode
1
0
Top and bottom cut in vertical direction
Up-conversion down-conversion statuses
C19
UD1
C20
UD2
C21
UD3
Down-conversion
status
Up-conversion
status
0
0
0
Squeeze mode
0
1
0
Side cut mode
1
0
0
Letter box mode
Stretch mode
Side panel mode
Top and bottom cut
in vertical direction
1
1
1
Any other combination
The statuses established by a multiple number of pins
in the special OUT menu list are displayed. Pin status
“1” signifies “active low” and “0” signifies “open.”
50P IN/OUT
ASSIGN
Summary of Contents for AJHD1700 - HD VTR W/24P