– 59 –
ERROR LOG function
ERROR LOG mode selection
In <Expansion mode selection> status with MODE/SEL button
g
pressed, ERROR LOG mode can be
selected.
When EXIT button
h
is pressed, ERROR LOG mode is canceled and changed to normal mode.
Outline
In case the following warning message is given during tape running, the time code and operation mode
as well as the warning message will be stored, which can be read in the form of a list at VTR status
display
3
.
It is possible to store up to 99 warnings. Also, in case of more than 99 warnings, it will be processed
according to the setting of setup menu No. 015 (AUTO STEP).
<Description of Menu>
Setup menu No.015 (AUTO STEP)
(Default setting is OFF)
In ERROR LOG function, warning can be stored up to 99 messages. If it exceeds the capacity,
processing mode will be selected for storage.
OFF:
Upper limit is 99 messages. Warning messages generated after that are not stored.
ON :
99 messages are stored. Warning messages given after that are stored in the place of 99th
message. Warning messages already stored are then shifted down in the direction of smaller
numbers in order.
• The image of storage with it set to ON is illustrated below.
Warning message to be stored
NO RF
SV NOT LOCKED
LOW RF
HIGH ERROR RATE
Description
Blank portion of tape was detected more than 1 sec. (Normal playback
mode)
Servo was unlocked for over 3 sec. (Record/Normal playback/Edit mode)
Envelop level detected was about 1/3 of the normal level for over 1 sec.
(Record/Normal playback/Edit mode)
Error rate worsened, and video or audio playback signal was subjected to
correction/calibration. (Normal playback mode)
Store No.
1/99
2/99
:
:
99/99
Warning stored
Warning 1
Warning 2
:
:
Warning 99
Store No.
1/99
2/99
:
:
99/99
Warning stored
Warning 2
Warning 3
:
:
Warning 100
Stored up to 99
messages, and
100th message
was given.