3-1
1. Preparation
1-1 Measuring Equipment and Special Tools.
No
Item
Recommend Stuff
Note
1
Digital Volt Meter
2
Frequency Counter
3
Registration Chart
VFK0673
4
High voltage prove
Use For High Voltage meas-
urement
5
Screwdriver(for adjust-
ment).Hex Wrench
The screwdriver use the made
by resin
The camera recorder becomes necessary separately for the all-kind control such as the aspect
changing to the others.
1-2 Adjustment preparation
Execute an adjustment under the following environment to attempt various adjustment precision improve-
ment.
(1)Horizontally set the viewfinder unit and Aim the CRT face side as follows.
A) Northern Hemisphere --------- North Direction
B) Southern Hemisphere -------- South Direction
(2) Adjust the angle of the eye piece by 45 as shown below.
Ground
45