153
Maintenance and Inspections: Maintenance
Ma
int
enan
ce
an
d Ins
pe
cti
on
s
LENS
Panasonic part number K1AY112JA001
1
RET-SW
On/off of the return video
RETURN ON:
GND
RETURN OFF:
OPEN
Maker part number
HR10A-10R-12SC(71)
(Hirose Denki)
2
REC-START/
STOP
Control for recording start/stop
3
GND
GND
4
IRIS-AUTO
On/off of the forced iris servo
SERVO ON:
+5 V±0.5 V
SERVO OFF:
OPEN
5
IRIS-CONT
Control output for the lens iris
F2.8: –6.2 V, F16: +3.4 V, CLOSE: +2.5 V
6
UNREG-12 V
+12 V power supply for the lens (Max. 1.5 A)
7
IRIS-POSI
Iris position signals
+3.4 V (F16) to +6.2 V (F2.8)
8
IRIS-G-MAX
IRIS REMOTE/LOCAL (AUTO) signals
REMOTE:
+5 V±0.5 V
LOCAL (AUTO):
GND
9
EXT-POSI
On/off of the built-in extender
EXTENDER ON:
GND
EXTENDER OFF: OPEN
10 ZOOM-POSI
Zoom position signals
11 FOCUS-POSI
Focus position signal
12 SPARE
Standby (not used)
GPS
Panasonic part number K1AY106J0001
1
GPS TXA
Transmission data from the GPS unit to the camera
Maker part number
HR10A-7R-6SC(73)
(Hirose Denki)
2
GPS RXA
Transmission data from the camera to the GPS unit
3
GPS VBAT
Backup power supply connector for the GPS unit
(DC +3.3 V)
4
REC START SW
Control signals of recording start/stop
5
GPS VCC
Power supply connector for the GPS unit (DC +3.3 V)
6
GPS GND
GND
START STOP START
+5 V
0 V
1
2
4
5
6
3
7
8
9
10
11
12
1
2
4
5
6
3
AJ-HPX2700G-VQT1V27_eng.book 153 ページ 2008年9月2日 火曜日 午後5時43分