30
500
VITC BLANK
0000
0001
BLANK
THRU
For setting whether to output the VITC signal to the position set by menu
item No.501 (VITC POS-1) and No.502 (VITC POS-2).
0: The VITC signal is not output.
1: The VITC signal is output.
<Note>
This setting is only effective for SD outputs (VIDEO output and SD SDI
output).
501
VITC POS-1
0000
:
0006
:
0010
10L
:
16L
:
20L
For setting the position where the VITC signal is to be inserted.
<Notes>
O
The same line as that set for menu item No.502 (VITC POS-2) cannot
be set.
O
This setting is only effective for SD outputs (VIDEO output and SD SDI
output).
502
VITC POS-2
0000
:
0008
:
0010
10L
:
18L
:
20L
For setting the position where the VITC signal is to be inserted.
<Notes>
O
The same line as that set for menu item No.501 (VITC POS-1) cannot
be set.
O
This setting is only effective for SD outputs (VIDEO output and SD SDI
output).
503
REGEN
0000
0001
REGEN
PRE
For setting the synchronization method of the internal time code generator.
0: The time code reader is synchronized to the time code which is read
from the tape.
1: The synchronization method can be preset by a front panel operation or
using the remote controller.
504
RUN MODE
0000
0001
REC
FREE
For setting the operation mode in which the internal time code generator
advances the time code.
0: The generator advances only during recording.
1: It advances while the power is on regardless of the operation mode.
505
TCG REGEN
0000
0001
0002
TC&UB
TC
UB
For setting the signal to be regenerated when the TCG (time code
generator) is in the regeneration mode.
0: Both the time code and user’s bit are regenerated.
1: Only the time code is regenerated.
2: Only the user’s bit is regenerated.
509
PHASE CORR
0000
0001
OFF
ON
For setting whether to control the phase compensation for the LTC output
during playback.
0: The phase compensation is not controlled.
1: The phase compensation is controlled.
508
BINARY GP
0000
0001
0002
0003
0004
0005
0006
0007
000
001
010
011
100
101
110
111
For setting the conditions under which the user’s bit in the time code
generated by TCG is to be used.
0: Not specified (character set is not specified).
1: ISO characters (8-bit character set compliant with ISO646, ISO2022)
2: Unassigned 1 (not defined)
3: Unassigned 2 (not defined)
4: Unassigned 3 (not defined)
5: Page/line
6: Unassigned 4 (not defined)
7: Unassigned 5 (not defined)
TIME CODE
Item
Setting
No.
Superimposed
display
No.
Superimposed
display
Description of setting
The underlining denotes the factory mode.
Setup Menus