– 33 (E) –
Adjusting the White Shading
Follow the procedure outlined below when the white shading needs to be re-adjusted.
White shading adjustment procedure
1
Mount a lens to the camera.
Be sure to also connect the lens cable.
2
Set the electronic shutter to OFF and the gain to L (0 dB).
3
If the lens has an extender, remove the extender.
4
Set the MENU SET/OFF switch from OFF to SET while holding down the SHIFT/ITEM and
UP buttons to open the menu.
Press the PAGE button until the MAIN menu screen 2 of 4 appears.
Press the SHIFT/ITEM button to move the cursor to the VF DISPLAY position.
Press the UP or DOWN button to open the VF DISPLAY page.
Set ZEBRA1 DETECT to 70%, ZEBRA2 DETECT to 85% and ZEBRA2 to SPOT. (Initial
setting mode)
Return the MENU SET/OFF switch from SET to OFF to close the menu.
Set the viewfinder’s ZEBRA switch to ON.
5
Shoot an evenly white paper.
Flickering occurs easily when fluorescent or mercury lamps, etc. are used for lighting.
Therefore, use a light source which does no produce flickering such as sunlight or halogen
lamps, etc.
6
Set the lens iris to manual and adjust the iris so that the ZEBRA pattern covers the entire
screen. If the light strikes the subject in an uneven manner, the ZEBRA pattern will not cover
a part of the screen. Therefore, adjust the position of the light source, etc. as necessary.
Check that the lens iris is between F4 to F11. If the lens iris is not within this range, adjust
the position of the light source, etc.
(Be sure to set the electronic shutter to OFF.)
GAIN: L (0 dB)
SHUTTER: OFF
SHIFT/ITEM
PAGE
MENU
|
Note
{
Adjusting the white
shading incorrectly will
seriously detract from
the camera’s picture
quality. Before starting
the re-adjustment pro-
cedure, carefully read
the description of the
white shading adjust-
ment steps contained in
the instruction manual.
If any points are un-
clear, consult with the
dealer from whom the
unit was purchased for
further clarification.
Also, make sure to al-
low sufficient time
when performing the
white shading re-ad-
justment procedure.