![Panasonic Aicure ANUJ5014 User Manual Download Page 41](http://html1.mh-extra.com/html/panasonic/aicure-anuj5014/aicure-anuj5014_user-manual_3654209041.webp)
Serial Communication
33
■
Serial Communication (PC selected, default settings)
Control items
(1) Read settings
a. LED1 to 4 cumulative data (irradiation period and number of irradiation times
b. Status (READY, BUSY1 to 4, WARNING and ERROR)
(2) Read and write settings
a. Type setup data (10)
b. Pattern setup data (10)
c. Start signal (pulse/status)
d. Irradiation setting (MULTI/ALL)
e. Type setting (10)
f. Busy signal (for a and b)
g. LED head fine adjustment (4)
h. Manual intensity (4)
(3) Online data read (automatic mode/manual mode)
a. Pattern No., Step No. (automatic) b. Irradiation time (automatic)
c. Alarm temp. display (auto., man.) d. Replacement remaining time (auto., man.)
e. Error No. (auto., man.)
f. Cumulative irradiation time (auto., man.)
g. Cumulative no. of irrad. times
h. READY signal (automatic)
i. LED head status (auto., man.)
(4) Online operation
a. Automatic start (4)
b. Automatic stop (4)
c. Manual LED selection (4)
d. Manual intensity setting (4)
e. Manual start/stop
f. Abnormal reset
(5) PC file management: Data managed by attaching file names to a. through
h. of (2), above (when using utility software).
■
Utility Software (PC-side operation software)
・
Software can be downloaded from the Web site.
・
Supports Windows 95/98/XP
Since item control and set data can be copied (file management), the same settings can be easily
written to multiple units.
Aicure PC operation screen
Summary of Contents for Aicure ANUJ5014
Page 8: ......
Page 35: ...Operation via External Signals 27 ...