Configuration
24
9.2
Configuring the Irradiation Patterns
The ANUJ5014/5012 Aicure can store up to 10 different LED irradiation
patterns.
The process from irradiation start to irradiation end can be divided into
up to 10 steps, and the UV light modulation ratio (intensity) and
irradiation time (time) can be set freely for each.
The available range is as follows.
UV light modulation ratio
0% to 120%
Irradiation time
0 to 999.9 s (seconds)
Do display the Pattern Setup screen, touch MENU
→
SETTING
→
PATTERN.
Touch BACK to return to the Setup screen.
1
Touch the pattern to configure (P1 to P10).
The Setup screen for the selected pattern appears.
2
Set the UV light modulation ratio (Intensity) and irradiation
time (time) for steps 1 and 2.
3
Touch the down arrow (
↓
) to configure the next steps (steps
¾).
Up to 10 steps can be configured.
Touch BACK to return to the previous screen.
4
To complete the steps, enter 0 s in the irradiation time
(time).
For example, to finish after 5 steps, set the time of step 6 to
0 s.
5
Touch BACK again to return to the Pattern Setup screen.