1. Enter EVR PG Shifter Adjustment mode, refer to "
HOW TO ENTER
EVR PG SHIFTER ADJUSTMENT MODE
."
2. Connect the channel-1 scope probe to TP3001 and the channel-2
scope probe to TP6205. Used TP6205 as a trigger.
3. Adjust value so that the trailing edge of the head switching pulse
is placed 6 H±1 H (0.38 ms±0.06 ms) before the start of the vertical
sync pulse.
4. Release EVR PG Shifter Adjustment Mode.
The adjusted value will be written to Memory IC (IC6004).
Fig. E5
7.3.6. SUB CONTRAST ADJUSTMENT
Purpose:
To set the optimum sub contrast level.
Symptom of Misadjustment:
The picture is too dark or too light.
Test Point :
Pin 5 of P6001 (TV/VCR Main C.B.A.) or TP49 (CRT C.B.A.)
Adjustment :
SUB CONTRAST (EVR)
Specification :
3.0 V[p-p]±0.1 V[p-p]
INPUT :
Video Input Jack,
Crosshatch Pattern Signal 1 V[p-p]
(75 terminated)
59
Summary of Contents for AG513F - COMBINATION VCR/TV
Page 1: ...ORDER NO MKE0304102C1 D1 Combination VCR AG 513F AG 520F SPECIFICATIONS 1 ...
Page 24: ...6 1 2 Disassembly Method Fig D2 24 ...
Page 25: ...Fig D3 25 ...
Page 26: ...6 1 2 1 Notes in chart 1 Removal of VCR Unit Fig D4 26 ...
Page 30: ...6 2 2 Inner Parts Location Fig J1 1 30 ...
Page 31: ...6 2 3 EJECT Position Confirmation Fig J1 2 31 ...
Page 32: ...6 2 4 Full Erase Head and Cylinder Unit Fig J2 32 ...
Page 70: ...70 ...
Page 73: ...11 2 MECHANISM BOTTOM SECTION 73 ...
Page 74: ...11 3 CASSETTE UP COMPARTMENT SECTION 74 ...
Page 75: ...11 4 CHASSIS FRAME SECTION 1 75 ...
Page 76: ...11 5 CHASSIS FRAME SECTION 2 76 ...
Page 77: ...11 6 PACKING PARTS AND ACCESSORIES SECTION 77 ...
Page 92: ...R572 ERJ6GEYJ331V MGF CHIP 1 10W 330 92 ...