fixture either clockwise or counterclockwise so that the envelope
is at maximum.
Fig. M7
6. Tighten Black Screw (D).
7. Remove the jumper between TP6003 and +5 V(TP6009).
Note:
Old type of H-Position Adjustment Driver (VFK0136) can be used for
this adjustment.
7.3. ELECTRICAL ADJUSTMENT
7.3.1. TEST EQUIPMENT
To do all of these electrical adjustments, the following equipment is required.
1. Dual-Trace Oscilloscope
Voltage Range: 0.001 V to 50 V/Div.
Frequency Range: DC to 50 MHz
Probes: 10:1, 1:1
2. NTSC Video Pattern Generator
3. DVM (Digital Volt Meter)
4. MTS/SAP Signal Generator
(TV Multi-Channel Sound Modulator (U.S.A.))
5. Frequency Counter
Frequency Range: 0 to 150 MHz
6. Plastic Tip Driver and Non-Metal Driver
7. Isolation Transformer (Variable)
8. VHS Alignment Tape (VFMS0003H6)
9. Degaussing Coil
10. White Pattern Generator
53
Summary of Contents for AG513F - COMBINATION VCR/TV
Page 1: ...ORDER NO MKE0304102C1 D1 Combination VCR AG 513F AG 520F SPECIFICATIONS 1 ...
Page 24: ...6 1 2 Disassembly Method Fig D2 24 ...
Page 25: ...Fig D3 25 ...
Page 26: ...6 1 2 1 Notes in chart 1 Removal of VCR Unit Fig D4 26 ...
Page 30: ...6 2 2 Inner Parts Location Fig J1 1 30 ...
Page 31: ...6 2 3 EJECT Position Confirmation Fig J1 2 31 ...
Page 32: ...6 2 4 Full Erase Head and Cylinder Unit Fig J2 32 ...
Page 70: ...70 ...
Page 73: ...11 2 MECHANISM BOTTOM SECTION 73 ...
Page 74: ...11 3 CASSETTE UP COMPARTMENT SECTION 74 ...
Page 75: ...11 4 CHASSIS FRAME SECTION 1 75 ...
Page 76: ...11 5 CHASSIS FRAME SECTION 2 76 ...
Page 77: ...11 6 PACKING PARTS AND ACCESSORIES SECTION 77 ...
Page 92: ...R572 ERJ6GEYJ331V MGF CHIP 1 10W 330 92 ...