108
Setup menu list (continued)
Item
Display
mode
Description of settings
1394 TC REGEN
P2
TAPE
(MCR/
VCR)
Selects the time code used for recording the signal from equipment connected
to the 1394 terminal.
ON:
Records using the time code of the signal input through the 1394 terminal.
OFF:
Records using the time code set in TC MODE/TCG/FIRST REC TC.
• If you select ON here, this has priority over the settings in TC MODE/TCG/
FIRST REC TC.
• If there is no input to the 1394 terminal, the camera follows the settings in TC
MODE/TCG/FIRST REC TC.
TC MODE
P2
TAPE
(Camera)
(MCR/
VCR)
(DUB)
Selects the correction mode of the internal time code generator.
DF:
Uses the drop frame mode.
NDF:
Uses the non-drop frame mode.
• The non-drop frame mode will be used when you set recording frame rate of
recording format to 24P, 24PA or 24PN.
TCG
P2
TAPE
(Camera)
(MCR/
VCR)
(DUB)
Sets the mode in which you advance the time code.
FREE RUN:
The time code is advanced regardless of the operation mode.
Records in the dubbing mode in such a way that the time codes of the clips
on the P2 card are carried over. User information is also carried over.
• When setting a frame rate other than 24P during operation with the
720P/24PN format or other than 30P during operation with the 720P/30PN
format, the FREE RUN operation for the time code will not be performed, and
the REC RUN operation will be performed instead.
REC RUN:
The time code is advanced only when recording.
FIRST REC TC
TAPE
(Camera)
(VCR)
(DUB)
Selects the time code to be recorded when you start recording.
REGEN:
Regenerates the time code on the tape to continue recording.
PRESET:
The time code on the tape is not regenerated. The value you set in TC
PRESET is used as the initial value to record the time code. However, if you
perform subsequent shooting, the time code will always be regenerated.
TC PRESET
P2
TAPE
(Camera)
(MCR/
VCR)
(DUB)
Sets the initial time code. This is activated when you select PRESET in FIRST
REC TC.
• Set the frame value to 0 or a multiple of 5 when you set recording frame rate
of recording format to 24P, 24PA or 24PN. If any other value, the recorded
time code will mis-match.
indicates the factory setting.