[STX] SPT:data [ETX]
Parameter
data = ghmmssff
(CTL data referenced)
g = Blank : With a positive (+)
value
– sign : With a negative (–)
value
h =
0—9
: Hours
mm = 00—59 : Minutes
ss =
00—59 : Seconds
ff =
00—29 : Frames
[STX] SPT [ETX]
Searches up to the position designated by the parameter.
The unit is placed in the STILL mode upon completion of
the playback.
If the designated position is before the current position, the
STILL mode is established without playing back the tape.
If the OSP (STOP) command or OEJ (tape EJECT)
command is assigned during operation, error code ERI is
returned from the unit.
If the unit’s operation mode has been changed by an
operation at its front panel, error code ERF is returned from
the unit.
If the tape reaches its start or end during operation, error
code ERP is returned from the unit.
When data differing from the reference data has been sent,
error code ERE is returned from the unit.
<Note>
This command is not acknowledged while a search control
command is being processed or while one of the following
modes is established.
EJECT, REC, REC PAUSE, REC CHECK, POWER OFF
RS-232C
$
Search control commands
Data transmitted by PC
Data returned from unit in response
Description of command
[STX] SCS:data [ETX]
Parameter
data = ghmmssff
(CTL data referenced)
g = Blank : With a positive (+)
value
– sign : With a negative (–)
value
h =
0—9
: Hours
mm = 00—59
: Minutes
ss =
00—59
: Seconds
ff =
00 (fixed): Frames
[STX] SCS [ETX]
Searches the counter value designated by the parameter.
The unit is set to STILL mode upon completion of the
search.
If the designated position is an illegal position (that is, the
target position does not exist), error code ERT is returned
from the unit, and the STOP mode is established.
If the OSP (STOP) command or OEJ (tape EJECT)
command is assigned during operation, error code ERI is
returned from the unit.
If the unit’s operation mode has been changed by an
operation at its front panel, error code ERF is returned from
the unit.
If the tape reaches its start or end during operation, error
code ERP is returned from the unit.
When data differing from the reference data has been sent,
error code ERE is returned from the unit.
<Note>
This command is not acknowledged while a search control
command is being processed or while one of the following
modes is established.
EJECT, REC, REC PAUSE, REC CHECK, POWER OFF