background image

MB1000 SPECIFICATIONS

1690 Corporate Circle, Petaluma, CA. 94954  •  800-472-5555  •  707-283-5900   

Fax 707-283-5901  •  www.panamax.com

L615 REV. B  10/09

© 2009 Panamax Inc. Panamax and the Panamax logo are registered US trademarks of Panamax. 

DESIGNED IN USA  • MADE IN CHINA

3 Year 

Product 

Warranty 

2 Year Battery 

Warranty 

C

US

LISTED

FRONT/BACK PANELS FEATURES

MB1000

WEIGHTS & MEASUREMENTS, QUANTITIES, UPC’S 

FOR ORDERING & SHIPPING

SINGLE MODEL MB1000

               Dimensions  

          Weight

L 17”   x   H 4”   x    W 13”           36 lbs.

SINGLE UNIT CARTON

          Dimensions  

          Weight                UPC

L 22.25  x  H 9.25”  x  W 17.5”      40 lbs.       050616-008518

MODEL: 

MB1000

MB1000 prevents critical equipment from losing setup configuration, 
stored data and hard-disk crashes.  Shuts off projection equipment 
via IR control to allow the projector bulbs to go through a proper 
cool-down cycle before shutting off.

UPS Output

 

Voltage   

 

              120 ± 5 V Simulated Sine Wave

Frequency                                                                             60 Hz ± 1%

UPS Output Capacity                                          1000VA 600W @ 0.6pf

UPS Backup Time                                                  3 minutes at full load

Transfer Time 

 

 

 

 

   < 10ms

Specifications subject to change due to product upgrades and improvements..

AC Power 

Current Rating 

 

 

 

 

          12 A

Surge Protection   

 

 

                900 Joules

Overvoltage Shutoff, fast rise   

 

 

  150 ± 5 V

Overvoltage Shutoff, slow rise  

 

 

  132 ± 5 V

Undervoltage Shutoff 

 

 

 

    90 ± 5 V

Automatic Voltage Regulation, 

Sensitive Mode Capture Range  

 

                98 – 135 V

Automatic Voltage Regulation, 

Sensitive Mode Output Range  

 

 

  120 ± 5%

Automatic Voltage Regulation, 

Standard  Mode Capture Range 

 

                93 – 145 V

Automatic Voltage Regulation, 

Standard Mode Output Range  

 

                120 ± 10%

Filtration   

        40dB min from 100kHz-2MHz

 

 

        65dB max @ 270kHz

Input

Voltage   

 

 

 

             85 – 137 Vac

Frequency 

 

 

 

                57 – 63 Hz

Power Switch

Press and hold the 

power button for 2 

seconds to turn the 

UPS ON or OFF.

IR Detector

IR Detector, for 

sampling IR remote 

control signals.

Menu Navigation Knob

Rotate clockwise to navigate to the 

next screen, counter-clockwise to 

return to the previous screen, push 

to select menu item.

Status Display

LCD displays status 

and menu 

navigation items.

Removable Battery 

Access Panel

Easy to remove for 

battery access and 

replacement.

Outlet Bank 1 

Indicator

Illuminated blue 

when outlet bank 1 

is switched on.

Outlet Bank 2 

Indicator

Illuminated blue 

when outlet bank 2 

is switched on.

Line Fault Indicator

This LED will illuminate in red to warn the user that a wiring 

problem such as a bad/missing ground or reversed wiring exists 

within the AC receptacle. If illuminated, disconnect all equipment 

and contact an electrician to insure outlet is properly wired.

10 Ft. AC Power Cord

USB to Computer

Outlet Bank 2 - Non-Critical-Load Outlets

Four battery powered, surge protected and AVR outlets 

for connected equipment insures temporary uninter-

rupted operation of connected equipment during a power 

failure. These outlets will shut off when the batteries 

drain to a designated level to reserve remaining battery 

charge from the critical load outlets.

Outlet Bank 1 - Critical Load Outlets

Four battery powered, surge protected 

and AVR outlets for critical-load 

equipment insures temporary 

uninterrupted operation of connected 

equipment during a power failure.

IR Control Section

Indicator LED’s – 

Indicates status IR 

Output Jacks – Standard 

1/8” (3.5mm) mono jack 

for connection to an IR 

flasher (IR flashers not 

included).

RS-232 Serial Communication Port

The serial port allows connection and communication between 

the UPS and an automation or computer system. This allows 

the installer to program a number of variables including the 

Critical Load Battery Threshold. See the software documenta-

tion for more information.

Circuit Breakers

 

Resettable circuit 

breakers provide 

optimal overload 

protection.

Ground 

Lug