background image

User's Manual

Para Systems, Inc.

1455 LeMay Dr.

Carrollton, TX 75007

Phone: 1-972-446-7363

Fax: 1-972-446-9011

Internet: minutemanups.com

UPS Sizing:  sizemyups.com

PN - 34000495 R1

Enspire Series UPS

EN350 / EN550

Summary of Contents for EN350

Page 1: ...User s Manual Para Systems Inc 1455 LeMay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000495 R1 Enspire Series UPS EN350 EN550 ...

Page 2: ...trols and Indicators 6 3 Installation 8 4 Operation 11 5 Troubleshooting 14 6 Replacing the Battery 15 7 Obtaining Service 18 8 Specifications 19 9 Limited Product Warranty 21 A1 Declaration of Conformity 22 Table Of Contents ...

Page 3: ...ock in conditions where the load equipment grounding cannot be verified disconnect the UPS from the AC wall outlet before installing a computer interface cable Reconnect the power cord only after all signaling connections are made CAUTION Connect the UPS to a two pole three wire grounded utility power AC wall outlet The receptacle must be connected to the appropriate branch protection circuit brea...

Page 4: ...interference to radio and television reception If this equip ment does cause interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the computer with respect to the receiver Move the computer away from the rece...

Page 5: ... Once the UPS reaches the LBW Low Battery Warning threshold the alarm will start beep ing The alarm cannot be silenced during the LBW alarm Once the UPS transfers back to the AC normal mode the alarm will reset back to the default setting Output Power Receptacles NEMA 5 15P W 4 ft cord Model Input Power Cord 4 NEMA 5 15R Battery Backup Surge 4 NEMA 5 15R Surge Only 1 Alarm Silencer Button Silences...

Page 6: ...ked on or damaged Typical battery life is 3 to 5 years Envi ronmental factors do affect battery life High temperatures poor utility power and frequent short duration discharges have a negative impact on battery life This UPS series is not intended for use in a computer room as defined in the Standard for the Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 Operating Tempera...

Page 7: ... the other end of the USB cable to the device that will be monitoring controlling the UPS and then follow the prompts on the screen NOTE When using the UPS s USB port with Windows XP 7 8 or 10 the Power Options in the Control Panel may need to be configured Connecting to the Communications Port is optional The UPS works properly with out this connection SYSTEM OVERVIEW This Standby UPS protects co...

Page 8: ...m will stop the On Battery LED will turn off and the AC normal LED will turn on LOW BATTERY WARNING When the batteries reach the predetermined level the Warning Fault LED will turn on and the alarm will sound two beeps every five seconds The audible alarm cannot be silenced during the LBW alarm This information is to inform the user that there is approximately two minutes of runtime remaining befo...

Page 9: ...RSONNEL ONLY CAUTION Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes and may be toxic QUALIFIED SERVICE PERSONNEL ONLY CAUTION Do not dispose of batteries in a fire The batteries may explode The batteries in this UPS are recyclable Dispose of the batteries properly The batteries contain lead and pose a hazard to the environment and human health if not dispose...

Page 10: ... with the UPS on the load will not be backed up To hot swap the battery module start with step number 6 1 Turn off the equipment that is plugged into the output of the UPS 2 Turn off the UPS 3 Unplug the UPS s AC power cord from the AC wall outlet 4 Unplug the equipment from the output receptacles of the UPS 5 Unplug the computer interface cable from the side panel of the UPS NOTE No tools are req...

Page 11: ...t It is important to pack the unit properly in order to avoid damage in transit Never use Styrofoam beads for a packing material a Include a letter with your name address day time phone number RMA number a copy of your original sales receipt and a brief desc ription of the problem 5 Mark the RMA on the outside of all packages The factory cannot accept any package without the RMA marked on the outs...

Page 12: ...ystems only covers faulty parts Para Systems products that are depot repaired or replaced pursuant to this warranty shall only be warranted for the unexpired portion of the warranty applying to the original product This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase The warranty shall be void if a the equipment is damaged by...

Page 13: ... C62 41 Category A1 UL1778 CSA 22 2 no 107 3 14 R 2014 FCC Class B Manufacturer s Name Para Systems Inc MINUTEMAN UPS Manufacturer sAddress 1455 LeMay Drive Carrollton Texas 75007 USA Type of Equipment Uninterruptible Power Supplies UPS Model No EN350 EN550 I hereby declare that the equipment specified above conforms to the above Directive s Place Carrollton Texas USA Date July 1 2016 Robert Calho...

Page 14: ...25 24 Notes Notes ...