background image

MAX® 5100-PM BACK PANEL FEATURES

1. Circuit Breaker: 
Automatically opens
when the current load
is greater than 15
Amps. Push to reset.

4. Outlet Bank 1 
Four always-on outlets with linear filtration 
technology (LiFT). Power will only be turned 
off under a fault condition. (See specifications 
for over-voltage and under-voltage thresholds) 
Power is cleaned by a two-stage balanced Pi 
filter which also provides noise isolation from 
Outlet Banks 2 and 3.

Universal TV Coaxial Jacks
3 pairs of bidirectional 
protection circuits optimized for 
satellite, cable, and antenna 
TV signal lines.

3. Outlet Bank 2 
Four isolated, switched outlets with linear filtration 
technology (LiFT) controlled by the front panel 
Power Button or the DC Trigger input. Bank 2 will 
turn on immediately and turn off after 10 seconds. 
LiFT EMI/RFI noise filtration is provided by a two-
stage balanced Pi filter which also provides noise 
isolation from Outlet Banks 1 and 3.

2. Outlet Bank 3
Two switched, high-current outlets controlled by 
the front panel Power Button or the DC Trigger 
input. Bank 3 has a 5 second turn on delay and 
turns off immediately. The High Current outlet 
provides power from a low impedance noise 
filtration circuit that does not limit the current to 
your equipment. Its output is noise isolated from all 
other outlet banks.

9. Main Power
Must be plugged into a 
properly wired & grounded 
3-wire outlet

.

11. Bank 1 Indicator Light
Normally ON, is lit when 
there is power present on the 
Bank 1 receptacles.

13. LAN Jacks
Protection circuits for 10/100 baseT 
Ethernet lines. Incoming LAN line MUST 
be plugged into the LINE jack. Patch cord 
to the equipment MUST be plugged into 
the EQUIP jacks. 1 LAN jack goes to the 
front panel output jack. 8 wire protection, 
50V clamping.

12. Voltage Sense Trigger 
Input
3.5mm (1/8”) mono mini-plug. 
Connect to a remote trigger 
device that uses a DC output 
to trigger a startup/shutdown  
sequence.

10. Ground Lug: 
Provides a common 
grounding point for 
equipment with separate 
ground leads

14. Phone Jacks
Protection circuits for standard telephone 
or pay-per-view lines. Phone circuit is 
autoresetting. Incoming phone cord MUST 
be plugged into the LINE jack. Patch cords 
to the equipment (satellite receiver, digital 
video recorder, telephone, etc.) MUST be 
plugged into the EQUIP jacks.

MAX® 5100-PM SPECIFICATIONS

UPC’S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING

General________________________________________________________________
Dimensions......................................17 in. W x 12.75 in. D x 3.5 in H, (4.1 in. Including feet)
Weight........................................................................................................................13.5 lbs.

AC Power_______________________________________________________________
Line Voltage.........................................................................................................120V, 60Hz
Total Current Capacity.....................................................................................................15 A
UL1449 Suppression Rating...........................................................................................330V
Protection Modes.............................................................................................L-N, L-G, N-G
Initial Clamping Level....................................................................................................200V
Energy Dissipation..............................................................................................2310 Joules
Peak Impulse Current........................................................................................90,000 Amps
Catastrophic Surge Circuit................................................................................................Yes
Thermal Fusing:...............................................................................................................Yes

Over-voltage shutoff....................................................................................142 VAC ± 5 VAC
Under-voltage shutoff....................................................................................90 VAC ± 2 VAC

EMI/RFI Noise Filtration___________________________________________________
Banks 1 & 2....................................................................................80 db, 100 KHz – 2 MHz
Bank 3, High Current Outlets..........................................................60 db, 100 KHz – 2 MHz

DC Trigger Input__________________________________________________________
Jacks............................................................................................... 3.5mm mono mini-plug
Voltage and Polarity........................................................................3 - 24V DC, bidirectional
Current Requirement....................................................................4.6 mA @3V, 58 mA @24V

LAN Circuits_____________________________________________________________
Clamping Level.............................................................................................................50V
Jacks..........................................................................................................................RJ-45
Wires Protected:.....................................................................................................8-Wires

USB Circuit_____________________________________________________________
Jacks.........................................................................................................................USB-A 
Power Delivery.............................................................................................500 mA @5VDC

Telephone Circuit________________________________________________________
Fuseless/Auto-resetting..................................................................................................Yes
Clamping Level.............................................................................................................260V
Capacitance....................................................................................................30pf (approx.)
Suppression Modes..........................................................................Metallic & Longitudinal
Connections................................................................................................................RJ-11
Lines Protected.......................................................................................2-Wire, Pins 4 & 5

Cable and Satellite TV Circuits______________________________________________
HD 1080 i/p Ready...........................................................................................................Yes
Bidirectional......................................................................................................................Yes
Shielded...........................................................................................................................Yes
Clamping Level................................................................................................................75V
Frequency Range.........................................................................................0MHz - 2.2 GHz
Insertion Loss............................................................................................................< 0.5 dB
Connections......................................................................................Female “F”, Gold Plated

MODEL M5100-PM

MASTER CARTON

UNIT CARTON

          Dimensions                           Weight                     Dimensions                  Weight                     UPC                     Qty            Dimensions                Weight                      UPC

  

         

17” x 12.75” x 3.5”                     13.5 lbs              23.75” x 19.25” x 9.25”       18 Lbs            0 50616 00817 4             1        23.75” x 19.75” x 9.75”     19 Lbs          5 00 50616 00817 9

       4.1” H with feet                                                                                                                                                                            

1690 Corporate Circle, Petaluma, CA. 94954  800-472-5555 or 707-283-5900  Fax 707-283-5901  www.panamax.com

© 2007 Panamax, Inc. Panamax, MAX, and the Panamax logo are registered US trademarks of Panamax

Design and specifications subject to change without notice due to product improvement.

L587 REV A  5/07